Left Atrial 4D Blood Flow Dynamics and Hemostasis following Electrical Cardioversion of Atrial Fibrillation
نویسندگان
چکیده
Background: Electrical cardioversion in patients with atrial fibrillation is followed by a transiently impaired atrial mechanical function, termed atrial stunning. During atrial stunning, a retained risk of left atrial thrombus formation exists, which may be attributed to abnormal left atrial blood flow patterns. 4D Flow cardiovascular magnetic resonance (CMR) enables blood flow assessment from the entire three-dimensional atrial volume throughout the cardiac cycle. We sought to investigate left atrial 4D blood flow patterns and hemostasis during left atrial stunning and after left atrial mechanical function was restored. Methods: 4D Flow and morphological CMR data as well as blood samples were collected in fourteen patients at two time-points: 2-3 h (Time-1) and 4 weeks (Time-2) following cardioversion. The volume of blood stasis and duration of blood stasis were calculated. In addition, hemostasis markers were analyzed. Results: From Time-1 to Time-2: Heart rate decreased (61 ± 7 vs. 56 ± 8 bpm, p = 0.01); Maximum change in left atrial volume increased (8 ± 4 vs. 22 ± 15%, p = 0.009); The duration of stasis (68 ± 11 vs. 57 ± 8%, p = 0.002) and the volume of stasis (14 ± 9 vs. 9 ± 7%, p = 0.04) decreased; Thrombin-antithrombin complex (TAT) decreased (5.2 ± 3.3 vs. 3.3 ± 2.2 μg/L, p = 0.008). A significant correlation was found between TAT and the volume of stasis (r2 = 0.69, p < 0.001) at Time-1 and between TAT and the duration of stasis (r2 = 0.34, p = 0.04) at Time-2. Conclusion: In this longitudinal study, left atrial multidimensional blood flow was altered and blood stasis was elevated during left atrial stunning compared to the restored left atrial mechanical function. The coagulability of blood was also elevated during atrial stunning. The association between blood stasis and hypercoagulability proposes that assessment of left atrial 4D flow can add to the pathophysiological understanding of thrombus formation during atrial fibrillation related atrial stunning.
منابع مشابه
4D flow CMR detects progressive improvement in ventricular function following cardioversion of atrial fibrillation
Background Atrial fibrillation (AF) causes impairment of cardiac hemodynamics and substantial cardiovascular morbidity. While AF is difficult to assess with cardiac gated CMR, successful electrical cardioversion of chronic AF is often followed by a transient period of atrial stunning where absence of mechanical atrial contraction, similar to that seen in AF, persists despite reinstitution of si...
متن کاملبررسی شیوع لخته دهلیز و گوشک دهلیز چپ در بیماران مراجعه کننده با فلوتر دهلیزی بر حسب بیماری زمینهای
Introduction: Most current evidence suggests the risk of left atrial and or auricular thrombi(LA &LAA) in patients with atrial flutter rhythm is similar to patients with atrial fibrillation, but there is still uncertainty in the risk level and the patient's need to receive anticoagulant therapy. Different studies report various frequencies for atrial thrombi and left atrial spontaneous echo-con...
متن کاملLeft atrial appendage-flow velocity predicts cardioversion success in atrial fibrillation.
Restoration of sinus rhythm by electrical cardioversion is a therapeutic option in appropriately selected patients with atrial fibrillation. It is important to determine predictors of electrical cardioversion outcome in patients with atrial fibrillation. Predictive value of clinical and conventional echocardiographic parameters for predicting cardioversion outcome is limited. The role of left a...
متن کاملLeft ventricular diastolic function after electrical cardioversion of atrial fibrillation.
In chronic atrial fibrillation (AF) left ventricular function may gradually diminish as a result of an intrinsic tachycardiomyopathy. This tachycardia induced cardiomyopathy is characterised by decreased systolic function, ventricular dilation, and raised ventricular filling pressures. In such patients left ventricular systolic function may gradually improve after electrical cardioversion. Litt...
متن کاملLeft atrial and left atrial appendage 4D blood flow dynamics in atrial fibrillation
BACKGROUND Atrial 4D flow magnetic resonance imaging was used for the characterization of left atrial (LA) and left atrial appendage (LAA) flow dynamics in patients with atrial fibrillation (AF). METHODS AND RESULTS 4D flow magnetic resonance imaging measured in vivo 3D blood flow velocities in 60 AF patients and 15 controls. Anatomic maps of LA and LAA stasis and velocity were calculated to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2017