CASE REPORT Benefit of Adaptive Optics Aberration Correction at Preferred Retinal Locus
نویسندگان
چکیده
Purpose. To investigate the effect of eccentric refractive correction and full aberration correction on both highand low-contrast grating resolution at the preferred retinal locus (PRL) of a single low-vision subject with a long-standing central scotoma. Methods. The subject was a 68-year-old women with bilateral absolute central scotoma due to Stargardt disease. She developed a single PRL located 25° nasally of the damaged macula in her left eye, this being the better of the two eyes. High(100%) and low-contrast (25 and 10%) grating resolution acuity was evaluated using four different correction conditions. The first two corrections were solely refractive error corrections, namely, habitual spectacle correction and full spherocylindrical correction. The latter two corrections were two versions of adaptive optics corrections of all aberrations, namely, habitual spectacle correction with aberration correction and full spherocylindrical refractive correction with aberration correction. Results. The mean high-contrast (100%) resolution acuity with her habitual correction was 1.06 logMAR, which improved to 1.00 logMAR with full spherocylindrical correction. Under the same conditions, low-contrast (25%) acuity improved from 1.30 to 1.14 logMAR. With adaptive optics aberration correction, the high-contrast resolution acuities improved to 0.89/0.92 logMAR and the low-contrast acuities improved to 1.04/1.06 logMAR under both correction modalities. The low-contrast (10%) resolution acuity was 1.34 logMAR with adaptive optics aberration correction; however, with purely refractive error corrections, she was unable to identify the orientation of the gratings. Conclusions. Correction of all aberrations using adaptive optics improves both highand low-contrast resolution acuity at the PRL of a single low-vision subject with long-standing absolute central scotoma. (Optom Vis Sci 2012;89:1–●●●)
منابع مشابه
Benefit of adaptive optics aberration correction at preferred retinal locus.
PURPOSE To investigate the effect of eccentric refractive correction and full aberration correction on both high- and low-contrast grating resolution at the preferred retinal locus (PRL) of a single low-vision subject with a long-standing central scotoma. METHODS The subject was a 68-year-old women with bilateral absolute central scotoma due to Stargardt disease. She developed a single PRL lo...
متن کاملImprovement in retinal image quality with dynamic correction of the eye's aberrations.
We measured the improvement in retinal image quality provided by correcting the temporal variation in the eye's wave aberration with a closed-loop adaptive optics system. This system samples the eye's wave aberration at rates up to 30 Hz. Correction of the eye's aberrations can be completed in 0.25-0.5 seconds, resulting in residual rms wave-front errors as low as 0.1 microns for 6.8 mm pupils....
متن کاملAdaptive optics simulation of intraocular lenses with modified spherical aberration.
PURPOSE Adaptive optics systems can be used to investigate the potential visual benefit associated with correcting ocular wave-front aberration. In this study, adaptive optics techniques were used to evaluate the potential advantages and disadvantages associated with intraocular lenses (IOLs) with modified spherical aberration profiles. METHODS An adaptive optics vision simulator was construc...
متن کاملChromatic aberration correction of the human eye for retinal imaging in the near infrared.
An achromatizing lens has been designed for the human eye in the near infrared range, from 700 to 900 nm, for retinal imaging purposes. Analysis of the performance of the lens, including tolerance to misalignments, has been mathematically accomplished by using an existing eye model. The calculations have shown a virtually perfect correction of the ocular longitudinal chromatic aberration, while...
متن کاملClosed-loop adaptive optics in the human eye.
We have developed a prototype apparatus for real-time closed-loop measurement and correction of aberrations in the human eye. The apparatus uses infrared light to measure the wave-front aberration at 25 Hz with a Hartmann-Shack sensor. Defocus is removed by a motorized optometer, and higher-order aberrations are corrected by a membrane deformable mirror. The device was first tested with an arti...