Controlling bubble motion over heated surface through evaporation momentum force to enhance pool boiling heat transfer
نویسنده
چکیده
Related Articles Dynamics of micro-bubble sonication inside a phantom vessel Appl. Phys. Lett. 102, 013702 (2013) Bubble-driven inertial micropump Phys. Fluids 24, 122003 (2012) Effect of viscosity and shear flow on the nonlinear two fluid interfacial structures Phys. Plasmas 19, 122105 (2012) Bubble nucleation on nanoto micro-size cavities and posts: An experimental validation of classical theory J. Appl. Phys. 112, 064904 (2012) Acoustic-wave effects in violent bubble collapse J. Appl. Phys. 112, 054910 (2012)
منابع مشابه
Experimental Study for Investigating the Mechanism of Heat Transfer near the Critical Heat Flux in Nucleate Pool Boiling
Heat transfer coefficient in nucleate pool boiling near critical heat flux at least one orderhigher than the convectional heat transfer modes. In this paper, an experimental setup isdesigned and fabricated to investigate the mechanism of heat transfer from boiling surface tobulk liquid near critical heat flux. The images of pool boiling near the high heat flux regionreveals that the individual ...
متن کاملExperimental Investigation in Pool Boiling Heat Transfer of Pure/Binary Mixtures and Heat Transfer Correlations
Nucleate pool boiling heat transfer coefficient have been experimentally measured on a horizontal rod heater for various liquid binary mixtures. Measurements are based on more than three hundred data points on a wide range of concentrations and heat fluxes. In this investigation, it has been confirmed that the heat transfer coefficient in boiling solutions are regularly less than those in p...
متن کاملPool Boiling Heat Transfer and Bubble Dynamics Over Plain and Enhanced Microchannels
Pool boiling is of interest in high heat flux applications because of its potential for removing large amount of heat resulting from the latent heat of evaporation and little pressure drop penalty for circulating coolant through the system. However, the heat transfer performance of pool boiling systems is not adequate to match the cooling ability provided by enhanced microchannels operating und...
متن کاملHighly subcooled pool boiling heat transfer at various gravity levels
A microscale heater array 2:7 mm 2:7 mm in size along with a video camera was used to provide subcooled pool boiling heat transfer measurements at gravity levels ranging from 1.8g to 10 g. The fluid was FC-72 at 1 atm and subcooled by nominally 36 C for all cases. A Terrier–Orion sounding rocket and the KC-135 aircraft were used to provide the microgravity and low-g environments, respectively. ...
متن کاملMechanism and Prevention of Scale Formation in Boilers
Nucleate boiling heat transfer coefficients may be strongly reduced by scale formation, even for conditions where the bulk foulant concentration is well below the saturation concentration. Due to the mechanism of micro-layer evaporation, the local concentration at the heat transfer surface can be considerably increased, causing the formation of scale and changes in bubble frequency and bubble d...
متن کامل