A New Fast Pi Controller Based Dstatcom under Balanced & Unbalanced Loading Conditions Using Instantaneous Synchronous Reference Theory

نویسندگان

  • D. MOHAN REDDY
  • T. GOWRIMANOHAR
  • D. Mohan Reddy
  • T. Gowrimanohar
چکیده

In this paper presents a fast new PI controlled DSTATCOM used to compensate for harmonic distortion in threephase system. The DSTATCOM employs a simple Method for the calculation of the reference compensation current based. The presented DSTATCOM is able to operate in balanced, unbalanced and Variable load conditions. Classic filters may not have satisfactory performance in fast varying conditions. But fast PI active power filter gives better results for harmonic minimization, reactive power compensation and power factor improvement. The proposed fast PIDSTATCOM maintains the THD well within IEEE519 standards.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Fast Acting PI based Multilevel DSTATCOM

The instantaneous response of the distribution static compensator (DSTATCOM) is very important while compensating rapidly varying balanced, unbalanced and nonlinear loads. Any change in the load affects the dc-link voltage directly. The proper operation of DSTATCOM requires variation of the dc-link voltage within the prescribed limits. Conventionally, a proportional-integral (PI) controller is ...

متن کامل

Comparative Power Quality Analysis of Different DSTATCOM Topologies

This paper presents the three topologies of three-phase four-wire DSTATCOM for reduction of harmonics, reactive power compensation, increasing power factor, which occur due to a nonlinear load, environment problem and polluted grid. The performances of the above topologies have been compared for the magnitude of source current, power factor improvement, DC-link voltage regulation, and total har...

متن کامل

Improving the performance of UPQC under unbalanced and distortional load conditions: A new control method

This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...

متن کامل

A New Control Algorithm of Shunt Active Power Filter under Distorted Grid Voltage and Unbalanced Supply Conditions

To achieve maximum possible power factor and by keeping total harmonic distortion (THD) within the acceptable limit. A new control algorithm of shunt active power filter under distorted grid voltage and unbalanced supply conditions is proposed. A new control algorithm renders the optimal compromise between harmonic free (HF) and unity power factor (UPF) by keeping the total harmonic distortion ...

متن کامل

A New Control Algorithm of Shunt Active Power Filter under Distorted Grid Voltage and Unbalanced Supply Conditions

To achieve maximum possible power factor and by keeping total harmonic distortion (THD) within the acceptable limit. A new control algorithm of shunt active power filter under distorted grid voltage and unbalanced supply conditions is proposed. A new control algorithm renders the optimal compromise between harmonic free (HF) and unity power factor (UPF) by keeping the total harmonic distortion ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013