Long-term fluctuation in short-wavelength automated perimetry in glaucoma suspects and glaucoma patients.

نویسندگان

  • N Hutchings
  • S L Hosking
  • J M Wild
  • J G Flanagan
چکیده

PURPOSE To determine the magnitude of the homogeneous, LF(Ho), and the heterogeneous, LF(He), components of the long-term fluctuation (LF) in glaucoma suspects and in stable primary open angle glaucoma (POAG) patients undergoing short-wavelength automated perimetry (SWAP) and to compare the magnitude of the SWAP LF components with those elicited by standard white-on-white (W-W) perimetry. METHODS The sample comprised 33 glaucoma suspects and 17 patients with early-to-moderate stable POAG who underwent W-W perimetry and SWAP at each of six visits over a mean period of 12.75 months (SD, 2.29). The LF(Ho), LF(He), and error components of the long-term fluctuation were determined between the third and seventh visual field examinations. The intervening visual field examinations and the optic nerve head parameters, derived both by stereo observation and by the Heidelberg Retinal Tomograph, were used to confirm stability over the follow-up period. RESULTS The LF(Ho) and LF(He) components were larger in the POAG patients than in the glaucoma suspects for both W-W perimetry and SWAP; the magnitude was independent of the depth of defect and of the short-term fluctuation. All three components of long-term fluctuation were greater for SWAP than for W-W perimetry, both in the glaucoma suspects and in the POAG patients. CONCLUSIONS SWAP exhibits greater long-term fluctuation than white-on-white perimetry. The usefulness of SWAP will be limited if the extent of this variability is not overcome in future statistical procedures developed to detect progressive visual field loss.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of glaucomatous visual field defects with automated perimetry.

A method to quantify different glaucomatous visual field defects is presented. Three visual field indices are calculated: the short-term fluctuation, the mean defect, and the corrected loss variation. The method was applied to visual fields tested with program JO on the Octopus automated perimeter. The indices of 130 glaucoma suspects and 50 glaucoma patients were compared with 100 normal contr...

متن کامل

[Importance of central corneal thickness when studying ocular hypertensive eyes, glaucoma suspects and preperimetric glaucomatous eyes].

PURPOSE To compare the central corneal thickness, measured with an ultrasound pachymeter, in normal subjects, those with ocular hypertension, glaucoma suspects and patients with preperimetric glaucoma. METHODS 61 normal eyes (control group), 131 eyes with ocular hypertension, 62 glaucoma suspects (optic nerve head morphology compatible with glaucoma) and 36 patients with preperimetric glaucom...

متن کامل

The effect of long-term intraocular pressure reduction on the differential light sensitivity in glaucoma suspects.

This study was undertaken to observe the effect on the differential light sensitivity in glaucoma suspects produced by a long-term reduction in intraocular pressure (IOP) with timolol maleate. The results are taken from an ongoing 6 year follow-up study of glaucoma suspects randomly selected for treatment and nontreatment. We present fine-grid meridional data, recorded every 4 months by automat...

متن کامل

Short-wavelength automated perimetry and standard perimetry in the detection of progressive optic disc cupping.

OBJECTIVE To compare progression in short-wavelength automated perimetry (SWAP) and white-on-white (standard) perimetry in eyes with progressive glaucomatous changes of the optic disc detected by serial stereophotographs. METHODS Forty-seven glaucoma patients with at least 2 disc stereophotographs more than 2 years apart, along with standard perimetry and SWAP examinations within 6 months of ...

متن کامل

Topography of the frequency doubling perimetry visual field compared with that of short wavelength and achromatic automated perimetry visual fields.

BACKGROUND Traquair described the topography of visual field sensitivity as a "hill" or "island" of vision. Achromatic automated perimetry (AAP) demonstrates this shape of the visual field in photopic conditions. Techniques claimed to target the magnocellular pathway (frequency doubling perimetry, FDP) and those using a stimulus targeting the koniocellular pathway (short wavelength (or blue on ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 42 10  شماره 

صفحات  -

تاریخ انتشار 2001