In vivo vs. ex vivo Magnetic Resonance Imaging In Mice
نویسنده
چکیده
The use of high-resolution MRI for the evaluation of structural changes in the mouse brain is rapidly gaining favor with researchers. The decision to use either in vivo or ex vivo imaging is often a practical one. For example, technical limitations, such as the availability of appropriate equipment to image in vivo, may force an investigator to use ex vivo imaging. Conversely, animal availability may limit the number of samples used at each time-point in an ex vivo experimental design, but not affect an in vivo design. But what if we were not limited by these considerations? What if we could decide which approach to take based entirely on which approach would yield the best data? In “Wanted dead or alive? The tradeoff between in vivo vs. ex vivo MR brain imaging in the mouse” presented by Lerch et al. (2012), this is exactly what is considered. Ex vivo imaging benefits from greater resolution and sensitivity due to the lack of constraints on imaging time, the use of tighter fitting coils, high concentration contrast agents, and a lack of movement artifacts. In vivo imaging allows for the longitudinal analysis of structural change, a benefit that can not be underestimated. Longitudinal studies lend themselves to other forms of statistical analysis, such as repeated measures ANOVAs, which can increase the statistical power of the studies. But beyond the obvious differences, how sensitive are these MRI measures to structural changes on the order of 5% of the total volume of a neuroanatomical structure? The authors describe a series of statistical analyses (based on imaging data they acquired) used to evaluate the tradeoffs between the use of in vivo (longitudinal) analysis and ex vivo (cross sectional) analysis. For a remarkably complex problem, the results are surprisingly straightforward. Firstly, ex vivo imaging is more precise than in vivo imaging. In cases where precise timecourse data is not required, ex vivo imaging provides better results. This is due to the lower within subject variability inherent to ex vivo imaging (higher resolution, no movement). However, if changes in absolute volumes or rates of change are required, in vivo imaging provides better information. Interestingly, in longitudinal experiments, the addition of more subjects, rather than more time-points, increases statistical power more rapidly. Secondly, the kind of analysis used matters. Spatial normalization to an unbiased consensus average, correcting for gross differences in brain size, decreases the population standard deviation markedly (by approximately 50%). Before spatial normalization, population standard deviations are about the same size as the effects to be observed. Clearly, spatial normalization is a crucial step in any form of volumetry. As in vivo imaging equipment and expertise become more common, the decision between the use of in vivo or ex vivo imaging begins to boil down to choosing the best tool for the job; ex vivo for precision, in vivo for time-course, and spatial normalization for all.
منابع مشابه
DNA Damages on Blood Cells After Cardiac Magnetic Resonance Imaging
Introduction: Along with the increased use of cardiac imaging at clinics there is increased attention to the potential risks related to the methods used like magnetic resonance (MR) and it cannot be ruled out that MR can alter DNA structure. The aim of this review is to assess the impact of routine cardiac magnetic resonance (CMR) scanning on DNA damages in human T lymphocytes....
متن کاملA New Theranostic System Based on Gd2O3 NPs coated Polycyclodextrin Functionalized Glucose for Molecular Magnetic Resonance Imaging (MMRI).
Introduction: Recent advances in nanoscience and biomedicine have attracted tremendous attention over the past decade to design and construct multifunctional nanoparticles that combine targeting, therapeutic, and diagnostic functions with a single platform to overcome the problems of conventional techniques for diagnosis and therapy with minimal toxicity. Materials ...
متن کاملIron-gold (Fe2O3@Au) core-shell nano-theranostic for magnetically targeted photothermal therapy under magnetic resonance imaging guidance
Introduction: Photothermal therapy (PTT) is a nanotechnology-assisted cancer hyperthermia approach in which the interaction between laser light and plasmonic nanoparticles generates a localized heating for thermoablation of the tumor. Recent efforts in the area of PTT follow two important aims: (i) exploitation of targeting strategies for preferential accumulation of plasmonic ...
متن کاملLinarin Inhibits the Acetylcholinesterase Activity In-vitro and Ex-vivo
Linarin is a flavone glycoside in the plants Flos chrysanthemi indici, Buddleja officinalis, Cirsium setosum, Mentha arvensis and Buddleja davidii, and has been reported to possess analgesic, antipyretic, anti-inflammatory and neuroprotective activities. In this paper, linarin was investigated for its AChE inhibitory potential both in vitro and ex vivo. Ellman’s colorimetric method was used for...
متن کاملA Method for Whole Brain Ex Vivo Magnetic Resonance Imaging with Minimal Susceptibility Artifacts
Magnetic resonance imaging (MRI) is a non-destructive technique that is capable of localizing pathologies and assessing other anatomical features (e.g., tissue volume, microstructure, and white matter connectivity) in postmortem, ex vivo human brains. However, when brains are removed from the skull and cerebrospinal fluid (i.e., their normal in vivo magnetic environment), air bubbles and air-ti...
متن کاملHigh-resolution magnetic resonance microscopy and diffusion tensor imaging to assess brain structural abnormalities in the murine mucopolysaccharidosis VII model.
High-resolution microscopic magnetic resonance imaging (μMRI) and diffusion tensor imaging (DTI) were performed to characterize brain structural abnormalities in a mouse model of mucopolysaccharidosis type VII (MPS VII). Microscopic magnetic resonance imaging demonstrated a decrease in the volume of anterior commissure and corpus callosum and a slight increase in the volume of the hippocampus i...
متن کامل