Sensitivity enhancement of enzyme-linked immunosorbent assay (ELISA) in capillary-based microdevice was achieved by the concentration of fluorescent final enzyme reaction product using capillary-isoelectric focusing (CIEF). In order to realize this, fluorescent substrate molecule, which can change its structure into ampholyte ion after an enzyme reaction, was newly synthesized and used. Approximately seven-fold enhancement of sensitivity and 1-2 orders of magnitude lower the detection limit were achieved.
منابع مشابه
Novel fluorescent probe for highly sensitive bioassay using sequential enzyme-linked immunosorbent assay-capillary isoelectric focusing (ELISA-cIEF).
This paper presents a novel rhodamine diphosphate molecule that allows highly sensitive detection of proteins by employing sequential enzyme-linked immunosorbent assay and capillary isoelectric focusing (ELISA-cIEF). Seven-fold improvement in the immunoassay sensitivity and a 1-2 order of magnitude lower detection limit has been demonstrated by taking advantage of the combination of the enzyme-...
متن کاملSimple and Highly-sensitive Enzyme Activity Assay Based on Reagent-release Capillary - Isoelectric Focusing (rrc-ief) towards the Development of Multi Analyte Sensing Micro Device Capable of Detecting Both Proteins and Enzyme Activities
We developed a simple and highly-sensitive enzyme activity assay method based on reagent release capillary – isoelectric focusing (RRC-IEF), that can be applied for the development of multi analyte sensing device allowing simple and highly sensitive multi assay of both proteins and enzyme activities.
متن کاملOn-line capillary isoelectric focusing hyphenated to native electrospray ionization mass spectrometry for the characterization of interferon-γ and variants.
The on-line hyphenation of Capillary IsoElectric Focusing (CIEF) with ElectroSpray Ionization Mass Spectrometry (ESI/MS) has been carried out in a non-denaturing detection mode at the CIEF-MS interface. This CIEF-MS coupling methodology relied on the use of 40% glycerol-water medium as anti-convective agent in the CE capillary and the addition of 10 mM ammonium acetate buffer, pH 5, as a volati...
متن کاملCapillary isoelectric focusing and high-performance cation-exchange chromatography compared for qualitative and quantitative analysis of hemoglobin variants.
We have developed two assays for complete analysis of hemoglobins (Hbs) in the field of hemoglobinopathies: a high-performance cation-exchange liquid chromatography (HPLC) assay on the weak cation-exchanger Poly Cat A and a two-step capillary isoelectric focusing (CIEF) assay on the neutral-coated capillary from Beckman in a narrow pH gradient. The resolution was satisfactory for both HPLC and ...
متن کاملDynamic kinetic capillary isoelectric focusing: a powerful tool for studying protein-DNA interactions.
A new method called dynamic kinetic capillary isoelectric focusing (DK-CIEF) is presented for the study of protein-DNA interactions. The method is based on CIEF with laser-induced fluorescence-whole column imaging detection in which protein-DNA complexes are separated with spatial resolution while dissociations of the complexes are dynamically monitored using a CCD camera with temporal resoluti...
متن کامل