Analysis of thoracic regional impedance changes using PCA approach
نویسندگان
چکیده
A multichannel impedance and one lead electrocardiographic recording system has been developed. The impedance measurement unit is built using a four-electrode technique. It consists of a sinusoidal, 40 kHz, current source and five measurement channels. Circumferential current electrodes have been located at a neck and an abdomen. Voltage measurement disk electrodes formed five two-electrode measurement ports. The impedance change waveforms (ICG) have been recorded simultaneously with ECG. The ICG waveforms have been analyzed using Principal Component Analysis (PCA). The examinations have been done for different ports configurations in relation to the heart. A dependence of obtained components on ports configurations has been found. Similar results have been obtained when examining healthy (test) persons.
منابع مشابه
A simple form of MT impedance tensor analysis to simplify its decomposition to remove the effects of near surface small-scale 3-D conductivity structures
Magnetotelluric (MT) is a natural electromagnetic (EM) technique which is used for geothermal, petroleum, geotechnical, groundwater and mineral exploration. MT is also routinely used for mapping of deep subsurface structures. In this method, the measured regional complex impedance tensor (Z) is substantially distorted by any topographical feature or small-scale near-surface, three-dimensional (...
متن کاملElectrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial
INTRODUCTION Computed tomography of the lung has shown that ventilation shifts from dependent to nondependent lung regions. In this study, we investigated whether, at the bedside, electrical impedance tomography (EIT) at the cranial and caudal thoracic levels can be used to visualize changes in ventilation distribution during a decremental positive end-expiratory pressure (PEEP) trial and the r...
متن کاملReciprocal splanchnic-thoracic blood volume changes during the Valsalva maneuver.
The Valsalva maneuver is frequently used to test autonomic function. Previous work demonstrated that the blood pressure decrease during the Valsalva maneuver relates to thoracic hypovolemia, which may preclude pressure recovery during phase II, even with normal resting peripheral vasoconstriction. We hypothesized that increased regional blood volume, specifically splanchnic hypervolemia, accoun...
متن کاملThe Effect of Technological Changes on Employment: Regional I-O SDA Approach
I n this study, the Regional Input- Output Structural Decomposition Analysis (I-O SDA) is used to investigate the effects of technological changes on employment in Sistan and Baluchestan Province of Iran during 2006-2011. This paper develops the SDA method to decompose the technological change from two viewpoints of supply and demand for intermediate inputs in each sector. These chan...
متن کاملImpedance cardiography revisited.
UNLABELLED Previously reported comparisons between cardiac output (CO) results in patients with cardiac conditions measured by thoracic impedance cardiography (TIC) versus thermodilution (TD) reveal upper and lower limits of agreement with two standard deviations (2SD) of approximately +/-2.2 l min(-1), a 44% disparity between the two technologies. We show here that if the electrodes are placed...
متن کامل