Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in adults: an update.
نویسندگان
چکیده
PURPOSE The Shin-Nippon SRW-5000 is an open view autorefractor that superseded the Canon R-1 autorefractor in the mid-1990 s and has been used widely in optometry and vision science laboratories. It has been used to measure refractive error, accommodation responses both statically and dynamically, off-axis refractive error, and adapted to measure pupil size. This paper presents an overview of the original 2001 clinical evaluation of the SRW-5000 in adults (Mallen et al., Ophthal Physiol Opt 2001; 21: 101) and provides an update on the use and modification of the instrument since the original publication. RECENT FINDINGS The SRW-5000 instrument, and the family of devices which followed, have shown excellent validity, repeatability, and utility in clinical and research settings. The instruments have also shown great potential for increased research functionality following a number of modifications. SUMMARY The SRW-5000 and its derivatives have been, and continue to be, of significant importance in our drive to understand myopia progression, myopia control techniques, and oculomotor function in human vision.
منابع مشابه
Evaluation of the measurement of refractive error by the PowerRefractor: a remote, continuous and binocular measurement system of oculomotor function.
BACKGROUND/AIM The technique of photoretinoscopy is unique in being able to measure the dynamics of the oculomotor system (ocular accommodation, vergence, and pupil size) remotely (working distance typically 1 metre) and objectively in both eyes simultaneously. The aim of this study was to evaluate clinically the measurement of refractive error by a recent commercial photoretinoscopic device, t...
متن کاملThe relationship between object spatial profile and accommodation microfluctuations in emmetropes and myopes.
The accommodation microfluctuations are thought to be used by the accommodation controller to obtain information about the direction and magnitude of the required response by monitoring changes in the contrast gradient of this image. The contrast gradient can be altered by presenting different spatial frequency (SF) targets to the eye. Twelve myopes (MYOs) and 12 emmetropes (EMMs) viewed sine a...
متن کاملEvaluation of an open-field autorefractor's ability to measure refraction and hence potential to assess objective accommodation in pseudophakes.
BACKGROUND To evaluate the accuracy of an open-field autorefractor compared with subjective refraction in pseudophakes and hence its ability to assess objective eye focus with intraocular lenses (IOLs). METHODS Objective refraction was measured at 6 m using the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K open-field autorefractor (five repeats) and by subjective refraction on 141 eyes impl...
متن کاملThe Changing Profile of Astigmatism in Childhood: The NICER Study.
PURPOSE We performed a prospective study of the changing profile of astigmatism in white school children in Northern Ireland. METHODS Of the 399 6- to 7-year-old and 669 12- to 13-year-old participants in Phase 1 of the Northern Ireland Childhood Errors of Refraction (NICER) study, 302 (76%) of the younger and 436 (65%) of the older cohort were re-examined three years later (Phase 2). Stratif...
متن کاملObjective accommodative amplitude and dynamics with the 1CU accommodative intraocular lens.
PURPOSE To compare the objective accommodative amplitude and dynamics of eyes implanted with the one-compartment-unit (1CU; HumanOptics AG, Erlangen, Germany) accommodative intraocular lenses (IOLs) with that measured subjectively. METHODS Twenty eyes with a 1CU accommodative IOL implanted were refracted and distance and near acuity measured with a logMAR (logarithm of the minimum angle of re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians
دوره 35 6 شماره
صفحات -
تاریخ انتشار 2015