Cationic polyelectrolyte copolymer modified polyurethane foam for flow injection preconcentration and separation of trace amounts of β-lactam antibiotics.
نویسندگان
چکیده
A more sensitive flow injection preconcentration method has been developed for the determination of four β-lactam antibiotics (BLAs) namely cefaclor, cefotaxime, amoxicillin and ampicillin in urine, pharmaceuticals and milk. A mini-column packed with PUF functionalized with the cationic polyelectrolyte, poly(N-chloranil N,N,N',N'-tetramethylethylene diammonium dichloride) PCTDD, was utilized for selective preconcentration. The detection limits with this method were 3.3, 3.8, 5.1 and 7.0 ng mL(-1) and enrichment factors were 38, 21, 39, and 36 for cefaclor, cefotaxime, amoxicillin and ampicillin, respectively with a sample throughput of 12 h(-1) for all BLAs. Moreover, the BLAs were successfully separated by isocratic elution using a micellar mobile phase. Application of the method developed has resulted in recovery values in the range 95%-109% (RSD≤8.7), 83%-99% (RSD≤9.7) and 91%-103% (RSD≤4.0) for urine, pharmaceuticals and milk samples, respectively.
منابع مشابه
Solid-phase Extraction Using Modified Carbon Nanotube and Cupferron Ligand for Preconcentration and Determination of Trace Amounts of Copper in Real Samples
A solid phase extraction procedure for simultaneous separation and preconcentration of traceamounts of Cu+2 ion from various real samples prior to its determination by flame atomicabsorption spectrometry has been developed. The proposed method is based on the utilization ofmultiwalled carbon nanotube in combination with Cupferron ligand as a solid phaseextractant. The influences of the analytic...
متن کاملFlow injection analysis-solid phase extraction (FIA-SPE) method for preconcentration and determination of trace amounts of penicillins using methylene blue grafted polyurethane foam.
A simple, fast, and fully automated FIA-SPE method with UV detection for the preconcentration and determination of the investigated penicillins has been developed. This paper provides adequate procedure for the preconcentration and determination of the studied compounds in pharmaceuticals and milk samples. Penicillins (penicillin G, amoxicillin, and ampicillin) are extracted in a mincolumn pack...
متن کاملM. F. El-Shahat, N. Burham; S.M.Abdel-Azeem;, Preconcentration and separation of copper, cobalt and manganese using neutral red grafted polyurethane foam
N. Burham; S.M.Abdel-Azeem; M. F. El-Shahat, Separation and determination of trace amounts of zinc, lead, cadmium and mercury in tap and qaroun lake water using polyurethane foam functionalized with 4-hydroxytoluene and 4-hydroxyacetophenone,Analytica Chimica Acta 579 (2006) 193–201. Abstract : N. Burham; S.M.Abdel-Azeem; M. F. El-Shahat, Determination of lead and cadmium in tap water and apple...
متن کاملApplication of Modified Nanoclay Sorbent for Separation and Preconcentration Trace Amount of Cobalt
The present article reports on the application of modified organo nanoclay as a green, easily prepared and stable solid sorbent for the preconcentration of trace cobalt ion in aqueous solution. The organo nanoclay was modified by adsorption of 5-(4-dimethyl amino-benzylidene) rhodanin reagent onto it. The sorption of Co2+ ions was quantitative in the pH range of 7.0 to 8.5, whereas quantitative...
متن کاملGallium trace on-line preconcentration/separation and determination using a polyurethane foam mini-column and flame atomic absorption spectrometry. Application in aluminum alloys, natural waters and urine.
A sensitive and selective flow injection time-based method for on-line preconcentration/separation and determination of gallium by flame atomic absorption spectrometry at trace levels was developed. The on-line formed gallium chloride complex is sorbed onto a polyether-type polyurethane foam mini-column, followed by on-line quantitative elution with isobutyl methyl ketone and direct introductio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Talanta
دوره 97 شماره
صفحات -
تاریخ انتشار 2012