Flow-injection chemiluminescent determination of metoclopramide hydrochloride in pharmaceutical formulations and biological fluids using the [Ru(dipy)(3)(2+)]-permanganate system.

نویسنده

  • Nawal A Al-Arfaj
چکیده

A flow-injection (FI) methodology using (2,2'-dipyridyl) ruthenium(II) [Ru(dipy)(3)(2+)] chemiluminescence (CL) was developed for the rapid and sensitive determination of metoclopramide hydrochloride. The method is based on the CL reaction of metoclopramide with Ru(dipy)(3)(2+) and KMnO(4) in a sulfuric acid medium. Under the optimum conditions, a calibration graph was obtained over the concentration range 0.005-3.5mugml(-1) with a limit of detection (S/N=2) of 1ngml(-1). The correlation coefficient was 0.99993 (n=8) with a relative standard deviation of 0.48% for 10 determinations of 1mugml(-1) of drug. The method was successfully applied to the determination of metoclopramide in pharmaceutical preparations and biological fluids after IP administration of 25mgkg(-1) dose to rats. The elimination half-life was 2.5+/-0.4h.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of phenolic sympathomimetic drugs in pharmaceutical samples and biological fluids by flow-injection chemiluminescence.

A rapid and highly sensitive flow-injection chemiluminometric method was developed for determination of 3 sympathomimetic drugs, namely, etilefrine hydrochloride, isoxsuprine hydrochloride, and prenalterol hydrochloride. The method is based on chemiluminescence induced by oxidation of drugs with acidified potassium permanganate in the presence of formic acid as a carrier. The calibration graphs...

متن کامل

Normal and reverse flow injection–spectrophotometric determination of thiamine hydrochloride in pharmaceutical preparations using diazotized metoclopramide

Simple and sensitive normal and reverse flow injection methods for spectrophotometric determination of thiamine hydrochloride (THC) at the microgram level were proposed and optimized. Both methods are based on the reaction between THC and diazotized metoclopramide in alkaline medium. Beer's law was obeyed over the range of 10-300 and 2-90 μg/mL, the limits of detection were 2.118 and 0.839 μg/m...

متن کامل

Flow-injection chemiluminometric analysis of some benzamides by their sensitizing effect on the cerium-sulphite reaction.

A simple, highly sensitive chemiluminescent method using flow injection is described for the determination of three substituted benzamides, namely: sulpiride, sultopride and tiapride. The method is based on the sensitizing effect of these drugs on the chemiluminometric oxidation of sulphite by cerium(IV). The different experimental parameters affecting the chemiluminescence intensity were caref...

متن کامل

Determination of phenylephrine hydrochloride by flow injection analysis with chemiluminescence detection.

A new method is proposed for the determination of phenylephrine hydrochloride by flow injection analysis with direct chemiluminescence detection. The method is based on the oxidation of the drug by potassium permanganate in sulfuric acid medium at 80 degrees C. The calibration graph is linear over the range 0.03-8 ppm phenylephrine hydrochloride, with a relative standard deviation (n = 51, 0.5 ...

متن کامل

Adaptive neuro-fuzzy inference system (ANFIS) applied for spectrophotometric determination of fluoxetine and sertraline in pharmaceutical formulations and biological fluid

The UV-spectrophotometric method of analysis was proposed for simultaneous determination of fluoxetine (FLX) and sertraline (SRT). Considering the strong spectral overlap between UV-Vis spectra of these compounds, a previous separation should be carried out in order to determine them by conventional spectrophotometric techniques. Here, full-spectrum multivariate calibrations adaptive neuro-fuzz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 62 2  شماره 

صفحات  -

تاریخ انتشار 2004