Improved design of low-pressure fluidic microvalves
نویسندگان
چکیده
Multilayer soft lithography (MSL) is used to fabricate monolithic elastomeric on-off microvalves by adopting a two-layer cross-channel architecture. The performance of microvalves is strongly dependent on the two-channel geometry (width, height and shape) and on the thickness of the interlayer membrane. Using a finite element model previously validated against experiments, we propose a new fluidic microvalve design, based on the concept of chemically swelling the thin interlayer membrane so as to induce two stable equilibrium configurations. The complete closure of the new valve may then be achieved by applying a much reduced actuation pressure, down to 1/4 of the pressure needed by the standard monostable design. The maximum stress in the interlayer membrane of the bistable valve also drops to 1/3 of the value corresponding to the standard design. (Some figures in this article are in colour only in the electronic version)
منابع مشابه
A Study on the Passive Microvalve Applicable to Drainage Device for Glaucoma
−This paper reports the design, modeling, fabrication and measurement of passive microvalves, which are applicable to glaucoma implants. The proposed microvalves were designed using fluidic theory. The microvalves consisted of microchannels and chambers. The microchannels had a constant fluidic resistance generating a pressure difference. Six kinds of microvalves were designed using fluidic equ...
متن کاملDesign and Simulation of a Fluidic Micro-Bio-Sensor Based on Resonator Array
In this paper, a fluidic biosensor with possibility to fabricate by Micro-Electro-Mechanical Systems (MEMS) technology is proposed for biomedical mass detection and lab-on-chip applications. This is designed by electromechanical coupling of harmonic micromechanical resonators with harmonic springers as a mechanical resonator array. It can disperse mechanical wave along the array by electrostati...
متن کامل3d-printed Microvalves and Micropumps
This paper describes a novel microvalve design that can be fabricated using stereolithography without need for the manual alignment and bonding steps required of PDMS microvalves. Multiple units of these microvalves can be arranged together and operated in tandem to perform fluid routing, switching, and pumping tasks. We demonstrate the performance of a four-valve fluid switch connected to a do...
متن کاملNumerical Analysis of Elastomeric Fluidic Microvalves
We present a finite element model of polydimethylsiloxane (PDMS) fluidic microvaJves. A valve is fabricated by assembling two patterned layers in a two-channel crossed architecture. The valve closes as a consequence of the motion of the intertayer membrane. The membrane is deformed by the pressure of the actuation fluid, flowing in one of the two channels. By using a soft rubber material model,...
متن کاملPMMA/PDMS valves and pumps for disposable microfluidics.
Poly(methyl methacrylate) (PMMA) is gaining in popularity in microfluidic devices because of its low cost, excellent optical transparency, attractive mechanical/chemical properties, and simple fabrication procedures. It has been used to fabricate micromixers, PCR reactors, CE and many other microdevices. Here we present the design, fabrication, characterization and application of pneumatic micr...
متن کامل