3D high-density localization microscopy using hybrid astigmatic/ biplane imaging and sparse image reconstruction.

نویسندگان

  • Junhong Min
  • Seamus J Holden
  • Lina Carlini
  • Michael Unser
  • Suliana Manley
  • Jong Chul Ye
چکیده

Localization microscopy achieves nanoscale spatial resolution by iterative localization of sparsely activated molecules, which generally leads to a long acquisition time. By implementing advanced algorithms to treat overlapping point spread functions (PSFs), imaging of densely activated molecules can improve the limited temporal resolution, as has been well demonstrated in two-dimensional imaging. However, three-dimensional (3D) localization of high-density data remains challenging since PSFs are far more similar along the axial dimension than the lateral dimensions. Here, we present a new, high-density 3D imaging system and algorithm. The hybrid system is implemented by combining astigmatic and biplane imaging. The proposed 3D reconstruction algorithm is extended from our state-of-the art 2D high-density localization algorithm. Using mutual coherence analysis of model PSFs, we validated that the hybrid system is more suitable than astigmatic or biplane imaging alone for 3D localization of high-density data. The efficacy of the proposed method was confirmed via simulation and real data of microtubules. Furthermore, we also successfully demonstrated fluorescent-protein-based live cell 3D localization microscopy with a temporal resolution of just 3 seconds, capturing fast dynamics of the endoplasmic recticulum.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU

Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...

متن کامل

High-density 3D single molecular analysis based on compressed sensing.

Single molecule fitting-based superresolution microscopy achieves sub-diffraction-limit image resolution but suffers from a need for long acquisition times to gather enough molecules. Several methods have recently been developed that analyze high molecule density images but most are only applicable to two dimensions. In this study, we implemented a high-density superresolution localization algo...

متن کامل

Fast Maximum Likelihood High-density Low-SNR Super-resolution Localization Microscopy

Localization microscopy such as STORM/PALM achieves the super-resolution by sparsely activating photoswitchable probes. However, to make the activation sparse enough to obtain reconstruction images using conventional algorithms, only small set of probes need to be activated simultaneously, which limits the temporal resolution. Hence, to improve temporal resolution up to a level of live cell ima...

متن کامل

Design and Manipulation 3D Imaging System by using Photodiode Grid

Introduction: Radiation imaging is one of the applicable methods in diagnostic medicine and nondestructive testing for industrial applications. In nondestructive 3D imaging, in addition to the radiation source, there is a requirement for a suitable detection system, data acquisition system, mechanical sections for moving objects, reconstruction algorithm and finally a computer for processing an...

متن کامل

Beyond Super-resolution Localization Microscopy: Extension to Three Dimensions, Dense Scenes, Fast Acquisition, and Drift-less Multicolor Thick Samples

In localization microscopy, super-resolution images are generated in a pointillistic fashion by identifying individual fluorescent molecules from thousands of images, where each frame contains only a sparse set of active emitters [1]. Initial demonstrations were limited to two dimensions, required long acquisition times, and relied on post-processing for drift correction. Furthermore, the sampl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biomedical optics express

دوره 5 11  شماره 

صفحات  -

تاریخ انتشار 2014