Late perforation by central venous cannulae.

نویسندگان

  • A M Henderson
  • E Sumner
چکیده

Three cases of hydrothorax secondary to late perforation of the superior vena cava by central venous cannulae are presented. The care of central venous cannulae is discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A survey of the use of ultrasound guidance in internal jugular venous cannulation.

It has been that suggested the use of two dimensional (2D) ultrasound to facilitate placement of central venous cannulae in the internal jugular vein improves patient safety and reduces complications. Since the introduction of the National Institute for Clinical Excellence Technology Appraisal Guideline Number 49 in 2002, promoting the use of ultrasound in placement of internal jugular venous c...

متن کامل

A single-center experience with luminal venous cannulae obstruction caused by clot formation during bypass.

Our institution experienced two bypass cases from January through December 2011 in which venous return was significantly variable and at times poor. Luminal clot formation in the venous cannulae was found in each case postbypass. These events were captured and monitored through our institution's Non-Routine Event Reporting Program and eventually reported to the Food and Drug Administration (FDA...

متن کامل

Percutaneous venovenous bypass in orthotopic liver transplantation.

Since January 1994, we have used percutaneous placement of both the subclavian and femoral cannulae to establish access for venovenous bypass during orthotopic liver transplantation. Percutaneous subclavian and femoral cannulae were used in 36 patients of which 5 had portal decompression by placement of a cannula in inferior mesenteric vein percutaneously through the abdominal wall. Intraoperat...

متن کامل

A Venous Catheter Complication: Venous Perforation and Lung Injury.

Central venous catheters are frequently used for different causes, like fluid infusions, haemodialysis, and measurement of central venous pressure. Complications that occur at the time or after the placement of these catheters can give harm to the patient or can cause need for a new attempt. Complications, like malfunction of the catheter, arterial puncture, haemothorax, or pneumothorax, can be...

متن کامل

The Need of Slanted Side Holes for Venous Cannulae

Well-designed cannulae must allow good flow rate and minimize nonphysiologic load. Venous cannulae generally have side holes to prevent the rupture of blood vessel during perfusion. Optimizing side hole angle will yield more efficient and safe venous cannulae. A numerical modeling was used to study the effect of the angle (0°-45°) and number (0-12) of side holes on the performance of cannulae. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood

دوره 59 8  شماره 

صفحات  -

تاریخ انتشار 1984