IPG strip-based peptide fractionation for shotgun proteomics.
نویسندگان
چکیده
Efficient fractionation of peptides is an essential prerequisite for comprehensive analysis of complex protein mixtures by shotgun mass spectrometry. The separation of peptides by isoelectric focusing is particularly attractive due to its orthogonality to reverse-phase HPLC. Here, we present a protocol for in-gel peptide isoelectric focusing using immobilized pH gradient strips. The method shows high resolving power for up to 1 mg of sample and is highly reproducible.
منابع مشابه
Increased proteome coverage by combining PAGE and peptide isoelectric focusing: Comparative study of gel-based separation approaches
The in-depth analysis of complex proteome samples requires fractionation of the sample into subsamples prior to LC-MS/MS in shotgun proteomics experiments. We have established a 3D workflow for shotgun proteomics that relies on protein separation by 1D PAGE, gel fractionation, trypsin digestion, and peptide separation by in-gel IEF, prior to RP-HPLC-MS/MS. Our results show that applying peptide...
متن کاملCysteinyl Peptide Capture for Shotgun Proteomics: Global Assessment of Chemoselective Fractionation
The complexity of cell and tissue proteomes presents one of the most significant technical challenges in proteomic biomarker discovery. Multidimensional liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based shotgun proteomics can be coupled with selective enrichment of cysteinyl peptides (Cys-peptides) to reduce sample complexity and increase proteome coverage. Here we evaluated the i...
متن کاملModeling the isoelectric focusing of peptides in an OFFGEL multicompartment cell.
In proteomic analysis of complex samples at the peptide level (termed shotgun proteomics), an effective prefractionation is crucial to decrease the complexity of the peptide mixture for further analysis. In this perspective, the high-resolving power of the IEF fractionation step is a determining parameter, in order to obtain well-defined fractions and correct information on peptide isoelectric ...
متن کاملComparison of a Salmonella typhimurium proteome defined by shotgun proteomics directly on an LTQ-FT and by proteome pre-fractionation on an LCQ-DUO.
Shotgun proteomics is rapidly becoming one of the most efficient and popular tools to examine protein expression in cells. Numerous laboratories now have a wide array of low- and high-performance mass spectrometry instrumentation necessary to complete proteome-wide projects. Often these laboratories have time and financial constraints that prohibit all projects from being conducted on high-perf...
متن کاملThe Agilent HPLC-Chip/6210 TOF LC/MS Enables Highly Accurate Profiling of Peptide Maps for Differential Expression Studies
Liquid chromatography/mass spectrometry (LC/MS) based workflows, with their analytical power and potential throughput, play an important role in the discovery and validation of protein-based biomarkers. Current LC/MS workflows for biomarker discovery range from the classical shotgun proteomics approach to protein profiling strategies. However, no single LC/MS workflow has been adopted by the sc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Methods in molecular biology
دوره 1156 شماره
صفحات -
تاریخ انتشار 2014