Evaluation of the i-STAT portable point-of-care analyzer for determination of blood gases and acid-base status in newborn calves.
نویسندگان
چکیده
OBJECTIVE To validate the i-STAT, a portable hand-held analyzer that allows point-of-care measurement of blood gases, acid-base, lactate, and other blood variables in food animal practice for analysis of blood samples of newborn calves. DESIGN Prospective observational study. SETTING University teaching hospital. MEASUREMENTS AND MAIN RESULTS A total of 271 venous blood samples were analyzed for PvO2 , PvCO2 , pH, base excess (BE), HCO3 , venous saturation of oxygen (SvO2 ), and total carbon dioxide (TCO2 ) using an i-STAT and a Rapidlab 248 bench top analyzer that served as the reference method. l-lactate was measured using the i-STAT as well as photometrically. Results from the i-STAT and the reference methods were compared. The analytes BE, HCO3 , and TCO2 showed a constant systematic error across the entire range with 2.3, 1.9, and 2.0 mmol/L lower values, respectively, than the values measured by the reference method. Based on the combined inherent imprecision of the 2 analyzers and after correcting the influences of systematic errors, the PvO2 , HCO3 , and SvO2 were within the acceptable limits in 76% to 91% of the cases. Ninety-five percent of the measurements of PvCO2 and BE were within acceptable limits. CONCLUSIONS The overall performance of the i-STAT was good except for BE, HCO3 , and TCO2 , thus limiting its usefulness in clinical studies. However this hand-held device allows rapid, reliable, and accurate point-of-care blood analyses and thus can be useful in bovine practice.
منابع مشابه
Evaluation of the i-STAT Portable Clinical Analyzer for point-of-care blood testing in the intensive care units of a university children's hospital.
We evaluated the analytical performance of the i-STAT Portable Clinical Analyzer (PCA), a point-of-care testing system consisting of a hand-held analyzer and single-use cartridges that measure different panels of electrolytes, metabolites, blood gases, and hematocrit in 65-100 microl of blood. Our objective was to determine whether PCA measurements at the bedside of patients in the neonatal and...
متن کاملBlood gas, oxygen saturation, pH, and lactate values in elasmobranch blood measured with a commercially available portable clinical analyzer and standard laboratory instruments.
Blood gas, pH, and lactate data are often used to assess the physiological status and health of fish and can often be most valuable when blood samples are analyzed immediately after collection. Portable clinical analyzers allow these measurements to be made easily in the field. However, these instruments are designed for clinical use and thus process samples at 37 degrees C. A few studies have ...
متن کاملEvaluation of the i-STAT point-of-care analyzer in critically ill adult patients.
Point-of-care analyzers may benefit therapeutic decision making by reducing turn-around-time for samples. This is especially true when biochemical parameters exceed the clinical reference range, in which acute and effective treatment is essential. We therefore evaluated the analytical performance of the i-STAT point-of-care analyzer in two critically ill adult patient populations. During a 3-mo...
متن کاملValidation of the i-STAT system for the analysis of blood gases and acid–base status in juvenile sandbar shark (Carcharhinus plumbeus)
Accurate measurements of blood gases and acid-base status require an array of sophisticated laboratory equipment that is typically not available during field research; such is the case for many studies on the stress physiology, ecology and conservation of elasmobranch fish species. Consequently, researchers have adopted portable clinical analysers that were developed for the analysis of human b...
متن کاملTEMPERATURE CORRECTION OF ARTERIAL BLOOD pH AND CO2 TENSION IN NEWBORN INFANTS: A NEW SOLUTION FOR AN OLD PROBLEM
The acid-base status and arterial blood gas change with temperature variation. To determine the changes in arterial pH and pC02, arterial blood samples of 50 neonates with different clinical conditions were examined at temperatures of 35 to 42°C with an increment of 0.5° C, which resulted in two nonlinear equations with perfect fit on data. The temperature correction factors of these equati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of veterinary emergency and critical care
دوره 24 5 شماره
صفحات -
تاریخ انتشار 2014