Development of the Top Hat Electric Propulsion Plume Analyzer (TOPAZ): Mass Analyzer Design and Preliminary Calibration Data

نویسندگان

  • Thomas Zurbuchen
  • Alec D. Gallimore
چکیده

The continued development and testing of the Top Hat Electric Propulsion Plume Analyzer (TOPAZ) is presented for high-powered electric propulsion far-field plume diagnostics. TOPAZ incorporates a ‘top hat’ design with an analyzer constant of 100 resulting in a wide energy range and a high energy resolution. The design of the electrostatic and mass analyzer sections for TOPAZ is described. The key performance parameters for the analyzer are compared with theory, and preliminary mass-per-charge measurements on an ion beam are presented. A time-of-flight (TOF) system is incorporated into TOPAZ, and in conjunction with the energy analyzer section, provide a partial velocity distribution function measurement capability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

IEPC 99-113 Development of a 45-Degree Parallel-Plate Electrostatic Energy Analyzer for Hall Thruster Plume Studies: Preliminary Data

Several successful Hall thruster plume studies have been conducted at the University of Michigan using a 45degree parallel-plate electrostatic energy analyzer mounted externally to the vacuum chamber. This requires the thruster to be in close proximity to the chamber walls potentially resulting in some set-up induced inaccuracies of the ion voltage distributions. A new design has been developed...

متن کامل

Retarding Potential Analyzer Design and Result Analysis for Ion Energy Distribution Measurement of the Thruster Plume in the Laboratory

Plasma plume will be produced and arrive at spacecraft when the electric thruster operates on orbit. It’s important to characterize the thruster plasma parameters because the plume has significant effects or hazards on spacecraft sub-systems and parts. Through the ground test data of the desired parameters, the major characteristics of the thruster plume will be achieved. Also it is very import...

متن کامل

Energy Analysis of a Hall Thruster Cluster

In an effort to understand the technical issues related to using a cluster of Hall effect thrusters to accomplish missions requiring very high-power electric propulsion systems, testing of four Busek BHT-200-X3 thrusters has begun at both the Air Force Research Laboratory and the University of Michigan. Two separate instruments, the parallel-plate electrostatic energy analyzer and the retarding...

متن کامل

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

Performance evaluation of a hybrid linear ion trap/orbitrap mass spectrometer.

Design and performance of a novel hybrid mass spectrometer is described. It couples a linear ion trap mass spectrometer to an orbitrap mass analyzer via an rf-only trapping quadrupole with a curved axis. The latter injects pulsed ion beams into a rapidly changing electric field in the orbitrap wherein they are trapped at high kinetic energies around an inner electrode. Image current detection i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005