Stress Reduction in Adjacent Level Discs via Dynamic Instrumentation: A Finite Element Analysis
نویسندگان
چکیده
BACKGROUND Conventional (rigid) fusion instrumentation is believed to accelerate the degeneration of adjacent discs by increasing stresses caused by motion discontinuity. Fusion instrumentation that employs reduced rod stiffness and increased axial motion, or dynamic instrumentation, may partially alleviate this problem, but the effects of this instrumentation on the stresses in the adjacent disc are unknown. We used a finiteelement model to calculate and compare the stresses in the adjacent-level disc that are induced by rigid and dynamic posterior lumbar fusion instrumentation. METHODS A 3-dimensional finite-element model of the lumbar spine was obtained that simulated flexion and extension. The L5-S1 segment of this model was fused, and the L4-L5 segment was fixed with rigid or dynamic instrumentation. The mechanical properties of the dynamic instrumentation were determined by laboratory testing and then used in the finite-element model. Peak stresses in the lumbar discs were calculated and compared. RESULTS The reduced-stiffness component of the dynamic instrumentation was associated with a 1% to 2% reduction in peak compressive stresses in the adjacent-level disc (at 45° flexion), and the increased axial motion component of this instrumentation reduced peak disc stress by 8% to 9%. Areas of disc tissue exposed to 80% of peak stresses of 6.17 MPa were 47% less for discs adjacent to dynamic instrumentation than for those adjacent to rigid instrumentation. CONCLUSIONS Reduced stiffness and increased axial motion of dynamic posterior lumbar fusion instrumentation designs result in an approximately 10% cumulative stress reduction for each flexion cycle. The effect of this stress reduction over many cycles may be substantial. CLINICAL RELEVANCE The cumulative effect of this reduced amplitude and distribution of peak stresses in the adjacent disc may partially alleviate the problem of adjacent-level disc degeneration.
منابع مشابه
Adjacent Disc Stress Following Floating Lumbar Spine Fusion: A Finite Element Study
STUDY DESIGN Experimental study. PURPOSE The study aimed to develop a finite element (FE) model to determine the stress on the discs adjacent to the fused segment following different types of floating lumbar spinal fusions. OVERVIEW OF LITERATURE The quantification of the adjacent disc stress following different types of floating lumbar fusions has not been reported. The magnitude of the st...
متن کاملLong-Term Effects of Segmental Lumbar Spinal Fusion on Adjacent Healthy Discs: A Finite Element Study
STUDY DESIGN Experimental study. PURPOSE The aim of the study was to develop a finite element (FE) model to study the long-term effects of various types of lumbar spinal interventions on the discs adjacent to the fused segment. OVERVIEW OF LITERATURE Earlier FE studies have been limited to one particular type of fusion and comparative quantification of the adjacent disc stresses for differe...
متن کاملEffect of pontic width on stress distribution in abutment teeth and their supporting structures by finite element analysis
Effect of pontic width on stress distribution in abutment teeth and their supporting structures by finite element analysis Dr. J. Ghanbarzadeh* - Dr. MR. Sabooni* - Dr. M. Keshavarz** * Assistant Professor of Dental Prostheses Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. ** Assistant Professor of Dental Prostheses Dept., Faculty of Dentistry, Kerman University of Medical...
متن کاملDynamic Fracture Analysis Using an Uncoupled Arbitrary Lagrangian Eulerian Finite Element Formulation
This paper deals with the implementation of an efficient Arbitrary Lagrangian Eulerian (ALE) formulation for the three dimensional finite element modeling of mode I self-similar dynamic fracture process. Contrary to the remeshing technique, the presented algorithm can continuously advance the crack with the one mesh topology. The uncoupled approach is employed to treat the equations. So, each t...
متن کاملAnalysis of non-connected piled raft foundations (NCPRF) with cushion by finite element method
For the optimum design of Piled Raft Foundations (PRF), the concept of settlement reducer piles has been applied. However, when these piles are connected to the raft, a high stress may develop in the relatively small number of piles. Therefore, an alternative approach is to disconnect the piles from the raft forming a new system called a non-connected or disconnected piled-raft foundation (NCPR...
متن کامل