k-t-Space accelerated myocardial perfusion.

نویسندگان

  • Bernd Jung
  • Matthias Honal
  • Jürgen Hennig
  • Michael Markl
چکیده

PURPOSE To investigate the performance of the recently introduced spatiotemporal parallel imaging technique called parallel MRI with extended and averaged generalized autocalibrating partially parallel acquisitions (GRAPPA) kernels (PEAK-GRAPPA) for myocardial perfusion measurements. MATERIALS AND METHODS A study with 11 patients with myocardial infarction was performed to compare nonaccelerated perfusion imaging, i.e., fully acquired k-space data, with the results of conventional GRAPPA and PEAK-GRAPPA with a net acceleration factor of 2.4 to 3.4. Signal time courses reflecting the passage of the contrast agent bolus in different regions of the heart were evaluated for these different reconstruction methods. RESULTS Reconstruction with PEAK-GRAPPA demonstrated considerably improved image quality compared to conventional GRAPPA. In addition, signal time courses for PEAK-GRAPPA demonstrated an excellent agreement compared to full k-space data, which is necessary for an accurate qualitative and quantitative assessment of myocardial perfusion. CONCLUSION Qualitative and quantitative results of patient measurements illustrate that the temporal fidelity of nonperiodic processes such as myocardial perfusion are preserved with PEAK-GRAPPA up to net acceleration factors of more than 3 while showing a superior image quality compared to conventional GRAPPA and a sliding-window reconstruction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accelerated imaging of rest and stress myocardial perfusion MRI using multi-coil k-t SLR: a feasibility study

Background In myocardial perfusion imaging (MPI), highly accelerated acquisition can be used towards reducing the compromises in the image quality (spatio-temporal resolutions, volume coverage, SNR) routinely observed with the current clinical protocols. In this study, we demonstrate the feasibility of a recent accelerated dynamic MRI scheme, k-t SLR (based on sparse and low rank properties) (L...

متن کامل

Clinical feasibility of accelerated, high spatial resolution myocardial perfusion imaging.

OBJECTIVES The aim of this study was to assess the clinical feasibility and diagnostic performance of an acceleration technique based on k-space and time (k-t) sensitivity encoding (SENSE) for rapid, high-spatial resolution cardiac magnetic resonance (CMR) myocardial perfusion imaging. BACKGROUND The assessment of myocardial perfusion is of crucial importance in the evaluation of patients wit...

متن کامل

Effect of Improving Spatial or Temporal Resolution on Image Quality and Quantitative Perfusion Assessment with k-t SENSE Acceleration in First-Pass CMR Myocardial Perfusion Imaging

k-t Sensitivity-encoded (k-t SENSE) acceleration has been used to improve spatial resolution, temporal resolution, and slice coverage in first-pass cardiac magnetic resonance myocardial perfusion imaging. This study compares the effect of investing the speed-up afforded by k-t SENSE acceleration in spatial or temporal resolution. Ten healthy volunteers underwent adenosine stress myocardial perf...

متن کامل

Relationship between the location of the most severe myocardial perfusion defects, the most severe coronary artery stenosis and the site of subsequent myocardial infarction [Persian]

This study evaluated the relationship between the location of the most severe coronary artery stenosis and the subsequent acute myocardial infarction (AMI). Methods: Of 1590 patients who were admitted with a diagnosis of AMI, we identified 44 patients who had undergone previous myocardial perfusion SPECT. Thirty-one of these patients also had previous coronary angiography. The relationshi...

متن کامل

Analysis of spatiotemporal fidelity in quantitative 3D first-pass perfusion cardiovascular magnetic resonance

BACKGROUND Whole-heart first-pass perfusion cardiovascular magnetic resonance (CMR) relies on highly accelerated image acquisition. The influence of undersampling on myocardial blood flow (MBF) quantification has not been systematically investigated yet. In the present work, the effect of spatiotemporal scan acceleration on image reconstruction accuracy and MBF error was studied using a numeric...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 28 5  شماره 

صفحات  -

تاریخ انتشار 2008