The effect of duration of follow-up and presence of competing risk on lifespan-gain from implantable cardioverter defibrillator therapy: who benefits the most?

نویسندگان

  • Claire E Raphael
  • Judith A Finegold
  • Anthony J Barron
  • Zachary I Whinnett
  • Jamil Mayet
  • Cecilia Linde
  • John G F Cleland
  • Wayne C Levy
  • Darrel P Francis
چکیده

BACKGROUND In at-risk patients with left ventricular dysfunction, implantable cardioverter defibrillators (ICDs) prolong life. Implantable cardioverter defibrillators are increasingly implanted for primary prevention and therefore into lower risk patients. Trial data have demonstrated the benefit of these devices but does not provide an estimate of potential lifespan-gain over longer time periods, e.g. a patient's lifespan. METHODS Using data from landmark ICD trials, lifespan-gain was plotted against baseline annual mortality in the individual trials. Lifespan-gain was then extrapolated to a time-horizon of >20 years while adjusting for increasing 'competing' risk from ageing and non-sudden cardiac death (pump failure). RESULTS At 3 years, directly observed lifespan-gain was strongly dependent on baseline event rate (r = 0.94, P < 0.001). However, projecting beyond the duration of the trial, lifespan-gain increases rapidly and non-linearly with time. At 3 years, it averages 1.7 months, but by 10 years up to 9-fold more. Lifespan-gain over time horizons >20 years were greatest in lower risk patients (∼5 life-years for 5% baseline mortality, ∼2 life-years for 15% baseline mortality). Increased competing risks significantly reduce lifespan-gain from ICD implantation. CONCLUSION While high-risk patients may show the greatest short-term gain, the dramatic growth of lifespan-gain over time means that it is the lower risk patients, e.g. primary prevention ICD implantation, who gain the most life-years over their lifetime. Benefit is underestimated when only trial data are assessed as trials can only maintain randomization over limited periods. Lifespan-gain may be further increased through advances in ICD device programming.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

The effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)

Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...

متن کامل

زندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیده‌شناسی

  Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European heart journal

دوره 36 26  شماره 

صفحات  -

تاریخ انتشار 2015