Strength and Modulus Degradation of CFRP Laminates from Fiber Misalignment
نویسندگان
چکیده
Fiber reinforced polymer (FRP) laminates are being used as external reinforcement for strengthening concrete members. The performance of unidirectional FRP laminates is highly dependent on fiber orientation with respect to applied load direction. In the case of fabrication by manual lay-up, it is possible to have fiber plies installed with improper orientation. In this project, the degradation of strength and modulus of carbon FRP laminates from fiber misalignment was investigated experimentally using tensile coupons. The specimens consisted of one and two plies of unidirectional carbon FRP impregnated with a two-component epoxy. The misalignment angles varied from 0 to 40 for the one-ply samples, and from 0 to 90 for one ply of the two-ply samples. The size effect on the strength and modulus was investigated for one-ply specimens with misalignments of 5 and 10. For these specimens, the ply width was maintained constant and the length was varied so that the aspect ratio ranged between 2 and 8. It was concluded that misalignment affects strength more than elastic modulus. However, provided that mechanical parameters are related to the cross sectional area of laminate with fibers continuous from end to end of the coupon, the degradation of strength can be accounted with a knock down factor that is independent of misalignment angle.
منابع مشابه
Analysis of Concrete Bridge Girders Strengthened with Cfrp Laminates under Service and Extreme Loading Conditions
Externally bonded carbon fiber reinforced polymer (CFRP) laminates are a feasible and economical alternative to traditional methods for strengthening and stiffening deficient reinforced concrete and prestressed concrete girders as shown in Fig. (1). Although extensive research has already been undertaken to investigate the behavior of CFRP strengthened bridge girders, the majority of work condu...
متن کاملThe optimum configuration of FRP laminates of coupling shear wall concerning the load capacity
Using of CFRP carbon sheets because of their high strength, lightness and ease of use have been very expanded in retrofitting concrete members. Including shear walls systems FRP can be used in order to rebuild or maintain the strength of an aged structural member. Repairing, or retrofitting of the intact structural member is conducted to enhance the structural resistance that was deteriorated d...
متن کاملBond and Splice Behavior of High Modulus Cfrp Materials Bonded to Steel Structures
Research on the use of CFRP materials for retrofit and strengthening of steel bridges and structures has increased in recent years. In order to implement these types of strengthening systems to longer span members, it is important to establish an effective method to splice adjacent lengths of CFRP laminates. This paper describes an experimental program to investigate the bond behavior of carbon...
متن کاملCarbon Fiber Post-Strengthening of Concrete Structures
Introduction In the 1970s, exterior bonded steel reinforcement was used sporadically to reinforce bridges to attain higher service load capacities. This steel post-strengthening system consisted of steel straps bonded with epoxies to the exterior of concrete beams. An alternative to the steel retrofit is woven carbon fiber reinforced polymer fabric applied in the same manner as steel. Carbon fi...
متن کاملFlexural Strengthening of Steel Bridges and Towers Using High Modulus CFRP Materials
Many steel structures are in need of strengthening due to reqUirements to increase carrying capacity and/or rehabili tation due to corrosion degradation. This paper summarizes the results of an investigation that has been conducted to evaluate the performance of carbon fiber reinforced polymer (CFRP) materials to increase the strength and stiffness of steel structures. Two types of specimens we...
متن کامل