Micron Size Laser-wire System at the Atf Extraction Line, Recent Results and Atf-ii Upgrade

نویسندگان

  • G. A. Blair
  • S. T. Boogert
  • G. Boorman
  • A. Bosco
  • D. Howell
  • L. J. Nevay
  • L. Corner
  • N. Delerue
  • B. Foster
  • F. Gannaway
  • M. Newman
  • R. Senanayake
  • R. Walczak
چکیده

The KEK Accelerator test facility (ATF) [1] extraction line laser-wire system has been upgraded last year allowing the measurement of micron scale transverse size electron beams. The most recent measurements using the upgraded system are presented. The ATF-II extraction line design [2] call for the major upgrade of the existing laser-wire system. We report on the hardware upgrades, including the major hardware upgrades to the laser transport, the laser beam diagnostics line, and the mechanical control systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Laser-wire System at the Atf Extraction Line*

A new laser-wire (LW) system has been installed at the ATF extraction line at KEK, Tsukuba. The system aims at a micron-scale laser spot size and employs a mode-locked laser system. The purpose-built interaction chamber, light delivery optics, and lens systems are described, and the first results are presented.

متن کامل

Status of the ATF extraction line laser-wire

The Accelerator Test Facility (ATF) at KEK offers a very low emittance micrometre sized beam of 1.28 GeV electrons close from the conditions expected at the International Linear Collider (ILC). The ATF should soon be able to provide a bunch spacing similar to that of the ILC. This accelerator being a test facility it is possible to have dedicated machine time with custom beam optics for our tes...

متن کامل

Wire Scanners for Small Emittance Beam Measurement in Atf

The wire scanners are used for a measurement of the very small beam size and the emittance in Accelerator Test Facility (ATF). They are installed in the extraction beam line of ATF damping ring. The extracted beam emittance are εx=1.3x10 m.rad, εy=1.7x10 m.rad with 2x10 electrons/bunch intensity and 1.3GeV energy[1]. The wire scanners scan the beam by a tungsten wire with beam repetition 0.78Hz...

متن کامل

Bnl Atf Ii Beamlines Design

The Brookhaven National Laboratory. Accelerator Test Facility (BNL ATF) is currently undergoing a major upgrade (ATF-II). Together with a new location and much improved facilities, the ATF will see an upgrade in its major capabilities: electron beam energy and quality and CO2 laser power. The electron beam energy will be increased in stages, first to 100-150 MeV followed by a further increase t...

متن کامل

Laser-based Profile Monitor for Electron Beams*

High performance TeV energy electron / positron colliders (LC) are the first machines to require online, non-invasive beam size monitors for micron and submicron for beam phase space optimization. Typical beam densities in the LC are well beyond the threshold density for single pulse melting and vaporization of any material, making conventional wire scanners ineffective. Using a finely focused,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009