Dynamic and static 99mTc-ECD SPECT imaging of subacute cerebral infarction: comparison with 133Xe SPECT.
نویسندگان
چکیده
UNLABELLED 99mTc-ethylcysteinate dimer (99mTc-ECD) SPECT imaging reportedly fails to show reflow hyperemia in patients with subacute stroke. This study attempts to determine the clinical usefulness of dynamic 99mTc-ECD SPECT in evaluating regional blood flow in subacute cerebral infarction and the kinetic behavior of 99mTc-ECD in infarct areas. METHODS 133Xe and consecutive dynamic and static 99mTc-ECD SPECT studies were performed on 24 patients with cortical infarction in the middle cerebral artery territory 13-15 d after the onset of a stroke. Image contrast between infarct and contralateral control areas on 99mTc-ECD tomograms (ECD uptake ratio) was compared with that on cerebral blood flow (CBF) images obtained using 133Xe inhalation (CBF ratio). RESULTS In all cases, ECD uptake ratios from static images were lower than CBF ratios. This tendency was obvious when CBF in the infarct area increased above the normal control value, and no significant correlation was found between ECD uptake ratios from static images and CBF ratios. Only in the infarct areas with CBF below the normal control value, however, was a significant correlation between the two maintained (r = 0.795; P = 0.0011). A very strong correlation was found between CBF ratios and ECD uptake ratios on both the first dynamic scan (36 s after injection) (r = 0.991; P < 0.0001) and the second dynamic scan (72 s after injection) (r = 0.945; P < 0.0001). The correlation coefficient decreased in a time-dependent manner, with no significant correlation observed after the fourth dynamic scan (144 s after injection). On the other hand, significant correlations were observed on all dynamic scans only in the infarct areas with CBF below the control value. CONCLUSION Super-early images of dynamic 99mTc-ECD SPECT provide a close imaging contrast with CBF and reveal reflow hyperemia in areas with irreversible changes produced by subacute stroke, which static 99mTc-ECD SPECT images fail to show. Decreased retention of the tracer in the infarct areas with hyperperfusion causes an underestimation of CBF on static 99mTc-ECD SPECT images. Given these results, we believe that dynamic 99mTc-ECD SPECT is an effective clinical tool to evaluate regional blood flow in subacute cerebral infarction.
منابع مشابه
Development of "super rapid dynamic SPECT," and analysis of retention process of 99mTc-ECD in ischemic lesions: comparative study with 133Xe SPECT.
To analyze the retention process of technetium-99m ethyl cysteinate dimer (99mTc-ECD) in normal and ischemic lesions, we developed a super rapid dynamic SPECT system based on the CERASPECT (DSI, Inc., Waltham, MA, USA). The system made it possible to take a SPECT series every 2 seconds. Each SPECT series contains a maximum of 16 slices (6.6 mm slice interval) in a matrix size of 32 x 32. The se...
متن کاملBrain single-photon emission CT studies using 99mTc-HMPAO and 99mTc-ECD early after recanalization by local intraarterial thrombolysis in patients with acute embolic middle cerebral artery occlusion.
BACKGROUND AND PURPOSE The brain distribution of 9mTc-hexamethylpropyleneamine oxime (HMPAO) correlates with regional brain perfusion, whereas 99mTc-ethyl cysteinate dimer (ECD) reflects not only perfusion but also the metabolic status of brain tissue. We compared 99mTc-ECD single-photon emission CT (SPECT) with 99mTc-HMPAO SPECT early after recanalization by local intraarterial thrombolysis (L...
متن کامل99mTc-bicisate and 99mTc-HMPAO SPECT imaging in early spontaneous reperfusion of cerebral embolism.
Two patients with a cerebral embolism were evaluated by using both 99mTc-ethyl cysteinate dimer (ECD, or Bicisate) and 99mTc-hexamethylpropyleneamine oxime (HMPAO) single-photon emission computed tomography (SPECT). In one patient, 99mTc-ECD SPECT images revealed hypoactivity in a reflow hyperemic area where an infarct was seen later on CT scans. In another patient, a reperfused area showed hyp...
متن کاملPrognostication of recovery in patients with acute ischemic stroke through the use of brain SPECT with Technetium-99m--labeled metronidazole.
BACKGROUND AND PURPOSE We hypothesized that technetium-99m-ethylene dicysteine-metronidazole (99mTc-EC-MN) localizes to brain tissue that is hypoxic but viable. This study prospectively evaluated the relationship between neurological outcome and uptake of 99mTc-EC-MN in peri-infarcted regions of the brain. METHODS Eight patients with acute ischemic stroke in the territory of the left middle c...
متن کاملBrain perfusion SPECT study with 99mTc-bicisate: clinical pitfalls and improved diagnostic accuracy with a combination of linearization and scatter-attenuation correction.
To evaluate the usefulness of a combination of linearization and scatter-attenuation correction on 99mTc-bicisate (ECD)-single photon emission tomographic (SPECT) images, both cerebral blood flow (CBF)-positron emission tomographic (PET) images and ECD-SPECT images from fifteen patients with chronic cerebral infarction were acquired. We measured radioactivity counts in regions of interest (ROIs...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 42 4 شماره
صفحات -
تاریخ انتشار 2001