I. INTRODUCTION Telerobotic surgical systems involve a slave robot, which interacts with the patient, and a master console, operated by the human surgeon. The slave robot reproduces the hand movements of the surgeon, who in turn needs to observe the operative environment with which the robot is interacting. The latter can be achieved by a combination of visual and haptic cues that flow from the operating table to the surgeon. Visual feedback is already available in commercial robotic surgery systems (e.g., the Intuitive Surgical da Vinci Si), but current surgical robots have very limited haptic feedback, despite its expected clinical benefits [1]. This omission is mainly due to the negative effect that haptic feedback has on the stability of the teleoperation loop. Haptic force feedback can in fact lead to undesired oscillations of the system, which interfere with the surgery and may be dangerous for the patient [2], [3]. In this respect, cutaneous feedback has recently received great attention in the haptics and medical research fields; delivering ungrounded sensory cues to the surgeon's skin conveys rich information and does not affect the stability of the teleoperation system [2], [4], [5]; Prattichizzo et al. [2] call this approach sensory subtraction, in contrast to sensory substitution, as it subtracts the kinesthetic part of the interaction to leave only the cutaneous cues. This paper presents a novel cutaneous feedback system for the da Vinci surgical robot, as shown in Fig. 1. Designed to provide planar fingertip deformation and vibration cues to the surgeon, our system is composed of a BioTac tactile sensor mounted to one of the robot's slave tools and a cutaneous display device attached to the corresponding master controller. Contact deformations and vibrations sensed by the BioTac are directly mapped to input commands for the cutaneous device's motors using a model-free data-driven algorithm. A preliminary version of the deformation part of the algorithm was presented in [6].
منابع مشابه
Tissue Identification Through Back End Sensing on da Vinci EndoWrist Surgical Tool1
Surgical robots are becoming more common in the operating room. Although surgeons utilize these robots for improved dexterity, scalable movements, and enhanced vision, they lose their sense of tactile and haptic feedback [1]. Okamura demonstrated a negative consequence of this by showing that forces exerted during robotic sutures significantly exceed that of hand sutures [2]. This excess in for...
متن کاملRaven Surgical Robot Training in Preparation for da Vinci® Use: A Randomized Prospective Trial
The rapid adoption of robotic assisted surgery challenges the pace at which adequate robotic training can occur due to access limitations to the da Vinci robot. Thirty medical students completed a randomized controlled trial evaluating whether the Raven robot could be used as an alternative training tool for the Fundamentals of Laparoscopic Surgery (FLS) block transfer task on the da Vinci robo...
متن کاملThe da Vinci robotic system for general surgical applications: a critical interim appraisal.
PRINCIPLES The recently introduced robotic surgical systems were developed to overcome the limitations of conventional minimally invasive surgery. We analyse the impact of the da Vinci robotic system on general surgery. METHODS The da Vinci operating robot is a telemanipulation system consisting of a surgical arm cart, a master console and a conventional monitor cart. Since its purchase in Ju...
متن کاملDa Vinci Xi Robot–Assisted Penetrating Keratoplasty
PURPOSE This study aims (1) to investigate the feasibility of robot-assisted penetrating keratoplasty (PK) using the new Da Vinci Xi Surgical System and (2) to report what we believe to be the first use of this system in experimental eye surgery. METHODS Robot-assisted PK procedures were performed on human corneal transplants using the Da Vinci Xi Surgical System. After an 8-mm corneal trephi...
متن کاملAnalysis of the Instrument Vibrations and Contact Forces Caused by an Expert Robotic Surgeon Doing FRS Tasks
INTRODUCTION The widespread growth of robotic minimally invasive surgery has led to the need for a standardized training curriculum. Toward that end, the Institute for Surgical Excellence is conducting the Fundamentals of Robotic Surgery (FRS) validation trial. This multi-site study is testing both novice and experienced surgeons using Intuitive Surgical da Vinci robots and robot simulators. Wh...