Complete roughness and conductivity corrections for the recent Casimir force measurement

نویسندگان

  • G. L. Klimchitskaya
  • Anushree Roy
  • V. M. Mostepanenko
چکیده

We consider detailed roughness and conductivity corrections to the Casimir force in the recent Casimir force measurement employing an atomic force microscope. The roughness of the test bodies — a metal plate and a sphere — was investigated with the AFM and the SEM respectively. It consists of separate crystals of different heights and a stochastic background. The amplitude of roughness relative to the zero roughness level was determined and the corrections to the Casimir force were calculated up to the fourth order in a small parameter (which is this amplitude divided by the distance between the two test bodies). Also the corrections due to finite conductivity were found up to the fourth order in relative penetration depth of electromagnetic zero point oscillations into the metal. The theoretical result for the configuration of a sphere above a plate taking into account both corrections is in excellent agreement with the measured Casimir force.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Roughness correction to the Casimir force : Beyond the Proximity Force Approximation

– We calculate the roughness correction to the Casimir effect as a second order perturbation of the parallel plates geometry. The metallic plates are described by the plasma model, with arbitrary values for the plasma wavelength, the plate separation and the roughness spectrum. The roughness correction is always larger than the result obtained in the Proximity Force Approximation. We derive sca...

متن کامل

New Experimental Results on the Casimir E ect

New experiments are discussed on measuring the Casimir force between metallic surfaces. One of them uses torsion pendulum and the other one | atomic force microscope. The claimed agreement of experimental data with a theory is analyzed. A 5% level of agreement obtained with a torsion pendulum is shown to be in contradiction with the values of surface roughness, nite conductivity and temperature...

متن کامل

Measurement of the Casimir force between dissimilar metals.

The first precise measurement of the Casimir force between dissimilar metals is reported. The attractive force, between a Cu layer evaporated on a microelectromechanical torsional oscillator and an Au layer deposited on an Al2O3 sphere, was measured dynamically with a noise level of 6 fN/sqrt[Hz]. Measurements were performed for separations in the 0.2-2 micro m range. The results agree to bette...

متن کامل

Higher order conductivity corrections to the Casimir force

The finite conductivity corrections to the Casimir force in two configurations are calculated in the third and fourth orders in relative penetration depth of electromagnetic zero oscillations into the metal. The obtained analytical perturbation results are compared with recent computations. Applications to the modern experiments are discussed. PACS codes: 03.70.+k, 12.20.Ds, 78.20.-e

متن کامل

ua nt - p h / 99 12 09 0 v 1 1 9 D ec 1 99 9 1 Higher order conductivity corrections to the Casimir force

The finite conductivity corrections to the Casimir force in two configurations are calculated in the third and fourth orders in relative penetration depth of electromagnetic zero oscillations into the metal. The obtained analytical perturbation results are compared with recent computations. Applications to the modern experiments are discussed.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999