A high-yield sampler for toxicological characterization of complex mixtures in combustion effluents.
نویسندگان
چکیده
Combustion sampling for toxicological assessment often requires that large (greater than 100 mg) lots of complex organic mixtures of wide volatility range be rapidly recovered from high temperature gases without contamination. A new sampler, meeting these criteria for studies of public health interest, has been developed and demonstrated. The device provides high sampling rates and intimate contacting of the samples stream with large volumes of a well-cooled, liquid solvent, dichloromethane (DCM). This promotes rapid organics dissolution from carrier gas and particulates and prompt dilution and quenching of the resulting solution, resulting in high organics collection efficiencies with minimal DCM losses. Solvent separation then remits large quantities of concentrated organics for chemical analysis and toxicological testing. One- to seven-hour interrogations of in-flame, post-flame, and flue gas regions gave 50- to 250-mg yields of complex organic mixtures. In side-by-side sampling of combustion exhaust, the DCM sampler provided higher yields of DCM solubles (identified with complex organic mixtures) and of S. typhimuirim mutagens (active without exogenous metabolizing agents) than did a filter/polymeric sorbent bed sampling train. The new sampler also collects polar and high volatile hydrocarbons such as benzaheyde, pentadiyne, m- and p-diethynyl-benzene, and 1-hexen-3,5-diyne. Nitration of naphthalene and pyrene in DCM solution (1 mg/mL each) was less than 1 part in 10(7) after a 345-min exposure to a bubbling flow of moist N2/air mixture (1:1 v/v) containing 107 ppm NO and 1.5 ppm NO2, indicating that for these condition a DCM sampler should resist artifactual nitration of aromatics. However, because of the very high bacterial mutagenicity of some nitroaromatics and the wide range of sampling conditions of environmental interest, nitration and all artifacts must still be scrutinized when using the DCM sampler. The DCM sampler is expected to contribute to public health impact assessments by facilitating detailed determinations of the identities, compositions, concentrations, sources, formation mechanisms, and biological activity of environmental toxicants in gaseous atmospheres.
منابع مشابه
General approach to the biological analysis of complex mixtures.
The study of potential health effects of combustion effluents involves identifying the substances present and estimating the probable health hazards of each. Unfortunately, this second step cannot be done by using present techniques. Approximations of health hazards by bacterial and human cell assays are being used to set priorities for further biological studies and to suggest needs for modifi...
متن کاملBiomedically relevant chemical and physical properties of coal combustion products.
The evaluation of the potential public and occupational health hazards of developing and existing combustion processes requires a detailed understanding of the physical and chemical properties of effluents available for human and environmental exposures. These processes produce complex mixtures of gases and aerosols which may interact synergistically or antagonistically with biological systems....
متن کاملHealth effects of the gas-aerosol complex. Report to Special Committee on Health and Ecological Effects of Increased Coal Utilization.
Combustion products derived from the burning of coal are definitely capable of producing adverse human health effects. No single component of the combustion product mixture is solely responsible. Rather, effects are due to a group of compounds, both gases and aerosols, in the effluents of stationary source combustion processes. Although incompletely defined, the individual components of the gas...
متن کاملChemical and toxicological characterization of residential oil burner emissions: II. Mutagenic, tumorigenic, and potential teratogenic activity.
Extracts of effluents from a modern residential oil burner have been evaluated in several toxicological assay systems. Bacterial mutagens were detected in extracts from both the particulate and vapor phase emissions. Effluents from continuous operation were an order of magnitude less mutagenic than those from cyclic (5 min on, 10 min off) operations. No difference in the yield of bacterial muta...
متن کاملToxicological approaches to complex mixtures.
This paper reviews the role of toxicological studies in understanding the health effects of environmental exposures to mixtures. The approach taken is to review mixtures that have received the greatest emphasis from toxicology; major mixtures research programs; the toxicologist's view of mixtures and approaches to their study; and the complementary roles of toxicological, clinical, and epidemio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Environmental Health Perspectives
دوره 90 شماره
صفحات -
تاریخ انتشار 1991