Effect of joint laxity on polyethylene wear in total knee replacement.
نویسندگان
چکیده
Experimental simulator studies are frequently performed to evaluate wear behavior in total knee replacement. It is vital that the simulation conditions match the physiological situation as closely as possible. To date, few experimental wear studies have examined the effects of joint laxity on wear and joint kinematics and the absence of the anterior cruciate ligament has not been sufficiently taken into account in simulator wear studies. The aim of this study was to investigate different ligament and soft tissue models with respect to wear and kinematics. A virtual soft tissue control system was used to simulate different motion restraints in a force-controlled knee wear simulator. The application of more realistic and sophisticated ligament models that considered the absence of anterior cruciate ligament lead to a significant increase in polyethylene wear (p=0.02) and joint kinematics (p<0.01). We recommend the use of more complex ligament models to appropriately simulate the function of the human knee joint and to evaluate the wear behavior of total knee replacements. A feasible simulation model is presented.
منابع مشابه
Wear of moderately cross-linked polyethylene fixed bearing knee replacements
Cross-linked polyethylene has been explored as an alternative to conventional polyethylene in total joint replacement in order to reduce wear volume and decrease failure through polyethylene wear debris induced osteolysis [1]. Due to the demands of a total knee replacement, moderately cross-linked polyethylene is recommended to retain mechanical properties [2]. This study aims to investigate th...
متن کاملWear debris pseudotumor following total knee arthroplasty: a case report
INTRODUCTION In patients who have undergone a total joint replacement, any mass occurring in or adjacent to the joint needs thorough investigation and a wear debris-induced cyst should be suspected. CASE PRESENTATION An 81-year-old man presented with a painful and enlarging mass at the popliteal fossa and calf of his right knee. He had had a total right knee replacement seven years previously...
متن کاملCurrent Concepts Review Wear in Total Hip and Knee Replacements
Before the advent of total joint replacement, patients who had end-stage arthritis of the lower extremities had unremitting pain and a greatly decreased functional capacity. In addition, they often were confined to a wheelchair and were dependent on the care of others. Today, the outcomes of primary total hip and knee replacement are predictable and usually excellent. Prosthetic joint replaceme...
متن کاملInvestigation of Wear Behavior of Biopolymers for Total Knee Replacements Through Invitro Experimentation
The average life span of knee prosthesis used in Total Knee Replacement (TKR) is approximately 10 to 15 years. Literature indicates that the reasons for implant failures include wear, infection, instability, and stiffness. However, the majority of failures are due to wear and tear of the prosthesis. The most common biopolymer used in TKR is Ultra High Molecular Weight Polyethylene (UHMWPE). Pr...
متن کاملResults of Revision Surgery and Causes of Unstable Total Knee Arthroplasty
BACKGROUND The aim of this study was to evaluate causes of unstable total knee arthroplasty and results of revision surgery. METHODS We retrospectively reviewed 24 knees that underwent a revision arthroplasty for unstable total knee arthroplasty. The average follow-up period was 33.8 months. We classified the instability and analyzed the treatment results according to its cause. Stress radiog...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 43 6 شماره
صفحات -
تاریخ انتشار 2010