Dosimetric differences were investigated among single and dual arc RapidArc and fixed-field intensity-modulated radiotherapy (f-IMRT) treatment plans for whole pelvic irradiation of lymph nodes. A total of 12 patients who had undergone radical surgery for cervical cancer and who had demonstrated multiple pelvic lymph node metastases were treated with radiotherapy. For all 12 cases, 7-field IMRT, single-arc RapidArc and dual-arc RapidArc were applied with 6 MV and 15 MV X-ray energies. The radiation dosimetric parameters for the different plans were compared with one another. All the plans met the clinical requirements. The homogeneity, conformity and external volume indices of f-IMRT and dual-arc RapidArc were better than for single-arc RapidArc (P < 0.05), while the differences between f-IMRT and dual-arc RapidArc were not significant. There were no significant differences in the radiation dose to organs at risk, except for the small bowel receiving >40 Gy (f-IMRT and dual-arc < single-arc, P < 0.05). The differences in dose distributions between the two applied X-ray energies for each of the modality plans were not significant. RapidArc plans resulted in fewer monitor units than the corresponding f-IMRT plans. Also, there were no differences between the two photon energies, except for a reduction in the number of MUs for 15 MV (P > 0.05). Compared to f-IMRT, no significant dosimetric benefits were found using RapidArc for whole pelvic lymph node irradiation. However, RapidArc has been associated with shorter treatment time and fewer monitor units, supporting the case for its safety and efficacy for pelvic irradiation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of radiotherapy techniques to reduce hematologic toxicity in whole pelvic radiation therapy

Introduction: Concurrent chemoradiotherapy (CRT) is a standard treatment method for patients with carcinoma of cervix. Despite admirable therapeutic results, acute hematologic toxicity (HT) is common with this regimen. Many studies evaluate the relationship between the bone marrow dosimetric parameters and the severity of HT and result shown that the low dose of bone marrow wou...

متن کامل

Out-Of-Field Dose Measurement and Second Cancer-Risk Estimation Following External Beam Radiotherapy and Brachytherapy for Cervical Cancer Treatment: A Phantom Study

Introduction: The present study aimed to measure the scatter and leakage dose received by out-of-field organs while delivering Radiotherapy (RT) treatment of cervical cancer. Moreover, this study estimated the risk of second cancer (SC). The doses to out-of-field organs were measured using a lithium fluoride (TLD 100) dosimeter while delivering External Beam Radiothera...

متن کامل

RapidArc: Initial experience in high grade glioma

Background: Identify the optimal technique of radiotherapy for patients with high grade glioma. Our initial year of experience with RapidArc radiation therapy. Materials and Methods: Planning CT scans of 50 patients with grade IV glioma were reviewed and three plan sets by 3D Conformal Radiotherapy (3DCRT), Intensity Modulated Radiotherapy (IMRT) and Rapid Arc (RA) were generated and the plans ...

متن کامل

Whole abdomen radiation therapy in ovarian cancers: a comparison between fixed beam and volumetric arc based intensity modulation

PURPOSE A study was performed to assess dosimetric characteristics of volumetric modulated arcs (RapidArc, RA) and fixed field intensity modulated therapy (IMRT) for Whole Abdomen Radiotherapy (WAR) after ovarian cancer. METHODS AND MATERIALS Plans for IMRT and RA were optimised for 5 patients prescribing 25 Gy to the whole abdomen (PTV_WAR) and 45 Gy to the pelvis and pelvic nodes (PTV_Pelvi...

متن کامل

Which technique for radiation is most beneficial for patients with locally advanced cervical cancer? Intensity modulated proton therapy versus intensity modulated photon treatment, helical tomotherapy and volumetric arc therapy for primary radiation – an intraindividual comparison

BACKGROUND To compare highly sophisticated intensity-modulated radiotherapy (IMRT) delivered by either helical tomotherapy (HT), RapidArc (RA), IMRT with protons (IMPT) in patients with locally advanced cervical cancer. METHODS AND MATERIALS Twenty cervical cancer patients were irradiated using either conventional IMRT, VMAT or HT; ten received pelvic (PEL) and ten extended field irradiation ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 54  شماره 

صفحات  -

تاریخ انتشار 2013