Measurement of effects of nasal and facial shields on delivered radiation dose for superficial x-ray treatments.

نویسندگان

  • Peter K N Yu
  • Martin J Butson
چکیده

Kilovoltage x-ray beams are used for the treatment of facial cancers when located on the patient's skin or subcutaneous tissue. This is of course due to the sharp depth dose characteristics of these beams delivering much lower doses at depth, than high energy x-ray beams. When treatment is performed, lead shields are often used within the nasal passage, or behind the lips and ears. These shields affect the backscattering patterns of the x-ray beams producing perturbations to upstream dose thus reducing delivered dose to the tumour. Experimental results using radiochromic films have shown that up to 10.5% ± 1.9% reduction in tumour dose can occur for field sizes less than 5 cm circle diameter for x-ray beams of 50 to 150 kVp. These results were confirmed using EGSnrc Monte Carlo techniques. Clinically more than 70% of treatments used fields of diameters less than 3 cm where the reductions were up to 6% ± 1.3%. Using a 1 cm diameter field, which can be used for skin cancer treatment on the nose, reductions up to 2.5% ± 1.3% were seen. Thus corrections need to be applied for dose calculations when underlying lead shields are used clinically in kilovoltage x-rays. The size of the reduction was also found to be dependent on the depth of the shield which will normally clinically vary from approximately 0.5 cm for nasal shields or behind eye lobes and up to approximately 1 cm for lips or cheek areas. We recommend that clinics utilize data for corrections to delivered dose in kilovoltage x-ray beams when lead shields are used in nasal passages, behind lips or behind ears for dose reduction. This can be easily and accurately measured with EBT2 Gafchromic film.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing X-ray dose reduction capability of silicon-bismuth micro- and nanocomposite shields using chest CT test

Comparison of radiation shields of different thicknesses and structures (especially different particle sizes of their constituents) is helpful to select an appropriate shield for patient protection in medical imaging tests particularly CT-scan. In this study micro- and nano-powders of bismuth were mixed with silicone matrix to make composite radiation shields for breast. The shields were provid...

متن کامل

Measurement of radiotherapy superficial X-ray dose under eye shields with radiochromic film.

Accurate measurement and knowledge of dose delivered under eye shield during superficial X-ray radiotherapy is required for patient peripheral dose assessment. Critical structures can include the cornea, lens and retina. Measurement of dose under eye shields has been historically performed with Thermoluminescent Dosimeters (TLD's) due to their small size and design. Restrictions include the ene...

متن کامل

Radiation attenuation properties of shields containing micro and Nano WO3 in diagnostic X-ray energy range

Background: It has recently been shown that the particle size of materials used for radiation shielding can affect the magnitude of radiation attenuation. Over the past years, application of nano-structured materials in radiation shielding has attracted attention world-wide. The purpose of this study was to investigate the shielding properties of the lead-free shields containing micro and nano-...

متن کامل

A Novel Design for Production of Efficient Flexible Lead-Free Shields against X-ray Photons in Diagnostic Energy Range

Background: Lead-based radiation shields are widely used in radiology departments to protect both workers and patients from any unnecessary exposure to ionizing radiation. Recently there has been a great deal of concern expressed about the toxicity of lead. Human lead toxicity is well documented. In that light, production of environmentally-friendly lead-free radiation shields with less weight ...

متن کامل

An in-vivo study on the energy dependence of X-ray biological effectiveness

Background: The International Commission on Radiological Protection (ICRP) has attributed the same relative risk for X and gamma radiations of all energies. Several studies have proven that the biological effect of low energy photon is more than that of higher ones. The assessment of risks is important due to the wide use of low energy X-rays for mammography screening and other diagnostic appli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 58 5  شماره 

صفحات  -

تاریخ انتشار 2013