Sub-8-minute cardiac four dimensional flow MRI using kat ARC and variable density signal averaging

نویسندگان

  • Peng Lai
  • Ann Shimakawa
  • Joseph Y Cheng
  • Marcus T Alley
  • Shreyas Vasanawala
  • Anja C Brau
چکیده

Background Recently, 3D CINE phase-contrast MRI (4D Flow) has demonstrated potential for quantitative measurement of blood flow of the cardiovascular systems in the entire thoracic trunk [1]. However, the needs of 4D flow for high resolution, large volume coverage & respiratory gating render very long scan time. This work intended to improve the data acquisition efficiency of free-breathing cardiac 4D flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single breathhold three-dimensional cardiac cine MRI with whole ventricular coverage and retrospective cardiac gating using kat ARC

Background For quantitative volumetric assessments of cardiac function, 3D cine images depicting motion of the entire ventricle in a complete cardiac cycle are needed. However, due to limited acceleration capability, breathheld 3D cine MRI is not obtainable using conventional parallel imaging. Several kt-acceleration methods have demonstrated high-acceleration capability for dynamic MRI by expl...

متن کامل

Improving cardiac cine MRI on 3T using 2D k-t accelerated auto-calibrating parallel imaging

Background Recently, 3D cine has gained attention due to its capability for single breath-hold volumetric measurement [1]. Nonetheless, conventional 2D cine maintains two intrinsic advantages, namely, its superior blood-myocardium contrast owing to blood in-flow effects and reduced SSFP banding artifacts with more localized slice-by-slice shimming. These advantages are more prominent at high fi...

متن کامل

Four-dimensional flow MRI using spiral acquisition.

Time-resolved three-dimensional phase-contrast MRI is an important tool for physiological as well as clinical studies of blood flow in the heart and vessels. The application of the technique is, however, limited by the long scan times required. In this work, we investigate the feasibility of using spiral readouts to reduce the scan time of four-dimensional flow MRI without sacrificing quality. ...

متن کامل

Enhancement of Noise Performance in Digital Receivers by Over Sampling the Received Signal

In wireless channel the noise has a zero mean. This channel property can be used in the enhancement of the noise performance in the digital receivers by oversampling the received signal and calculating the decision variable based on the time average of more than one sample of the received signal. The averaging process will reduce the effect of the noise in the decision variable that will approa...

متن کامل

The influence of flow and motion in MRI of diffusion using a modified CE-FAST sequence.

Severe motion and flow artifacts are a problem in MRI of diffusion in vivo due to the application of strong magnetic field gradients. Here it is shown that image artifacts can be removed by using a modified fast-scan MRI sequence (CE-FAST) in conjunction with averaging of diffusion-weighted images. In phantom studies slow (coherent) flow (less than 1 mm s-1) in the presence of strong diffusion ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2015