Breast Contrast Enhanced MR Imaging: Semi-Automatic Detection of Vascular Map and Predominant Feeding Vessel
نویسندگان
چکیده
PURPOSE To obtain breast vascular map and to assess correlation between predominant feeding vessel and tumor location with a semi-automatic method compared to conventional radiologic reading. METHODS 148 malignant and 75 benign breast lesions were included. All patients underwent bilateral MR imaging. Written informed consent was obtained from the patients before MRI. The local ethics committee granted approval for this study. Semi-automatic breast vascular map and predominant vessel detection was performed on MRI, for each patient. Semi-automatic detection (depending on grey levels threshold manually chosen by radiologist) was compared with results of two expert radiologists; inter-observer variability and reliability of semi-automatic approach were assessed. RESULTS Anatomic analysis of breast lesions revealed that 20% of patients had masses in internal half, 50% in external half and the 30% in subareolar/central area. As regards the 44 tumors in internal half, based on radiologic consensus, 40 demonstrated a predominant feeding vessel (61% were supplied by internal thoracic vessels, 14% by lateral thoracic vessels, 16% by both thoracic vessels and 9% had no predominant feeding vessel-p<0.01), based on semi-automatic detection, 38 tumors demonstrated a predominant feeding vessel (66% were supplied by internal thoracic vessels, 11% by lateral thoracic vessels, 9% by both thoracic vessels and 14% had no predominant feeding vessel-p<0.01). As regards the 111 tumors in external half, based on radiologic consensus, 91 demonstrated a predominant feeding vessel (25% were supplied by internal thoracic vessels, 39% by lateral thoracic vessels, 18% by both thoracic vessels and 18% had no predominant feeding vessel-p<0.01), based on semi-automatic detection, 94 demonstrated a predominant feeding vessel (27% were supplied by internal thoracic vessels, 45% by lateral thoracic vessels, 4% by both thoracic vessels and 24% had no predominant feeding vessel-p<0.01). An excellent agreement between two radiologic assessments (k = 0.81) and between radiologic consensus and semi-automatic assessment (k = 0.80) was found to identify origin of predominant feeding vessel. An excellent reliability for semi-automatic assessment (Cronbach's alpha = 0.96) was reported. CONCLUSIONS Predominant feeding vessel location was correlated with breast lesion location: internal thoracic artery supplied the highest proportion of breasts with tumor in internal half and lateral thoracic artery supplied the highest proportion of breasts with lateral tumor.
منابع مشابه
Automatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI
Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...
متن کاملQuantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging
Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...
متن کاملA fully automatic multiscale 3-dimensional Hessian-based algorithm for vessel detection in breast DCE-MRI.
OBJECTIVES The objectives of this study were to develop a fully automatic method for detecting blood vessels in dynamic contrast-enhanced magnetic resonance imaging of the breast on the basis of a multiscale 3-dimensional Hessian-based algorithm and to evaluate the improvement in reducing the number of vessel voxels incorrectly classified as parenchymal lesions by a computer-aided diagnosis (CA...
متن کاملRecent Advances in PET-MR Hybrid contrast agent
Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...
متن کاملMAMMALYZER: An Approach for Automatic Detection of Breast Cancer by Analyzing Contrast-Enhanced MRI Mammographs
This is a report on a new integrated system 1 for the automatic analysis of MRI-breast images for the early detection of breast cancer. The system operates on images taken using the method of dynamic contrast-enhanced MRI. Suspicious lesions in the breast are automatically marked with a special colour, thus directing the attention of the physicians towards the critical breast regions. The medic...
متن کامل