Thermally stimulated luminescence and EPR studies on topaz.

نویسندگان

  • Divanizia N Souza
  • José Fernandes de Lima
  • Mário Ernesto G Valerio
  • Linda V E Caldas
چکیده

In the present work, electron paramagnetic resonance (EPR) spectra and thermoluminescence (TL) emission of colourless natural topaz from Santo Antônio do Jacinto, Brazil, was studied as a function of thermal treatment and gamma irradiation dose, focussing on the use of this material as a radiation dosimeter. EPR measurements on "as-received" samples at room temperature provided signals in the region of about 500 at 5,000 G. The signal located around g approximately equal to 2, frequently attributed to (AlO(4))(0), increased with additional gamma dose and disappeared after thermal treatment at 500 degrees C for 1h. Irradiation after thermal treatment recovered this signal. The decay promoted by isochronal thermal treatment showed the (AlO(4))(0) defects to be directly related to the TL glows peaks. The variation of EPR spectrum with annealing temperature prior to irradiation showed that the variation of TL sensitivity is a consequence of the variation of the (AlO(4))(0) population.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermally Activated Delayed Fluorescence in a Y3N@C80 Endohedral Fullerene: Time‐Resolved Luminescence and EPR Studies

The endohedral fullerene Y3 N@C80 exhibits luminescence with reasonable quantum yield and extraordinary long lifetime. By variable-temperature steady-state and time-resolved luminescence spectroscopy, it is demonstrated that above 60 K the Y3 N@C80 exhibits thermally activated delayed fluorescence with maximum emission at 120 K and a negligible prompt fluorescence. Below 60 K, a phosphorescence...

متن کامل

Use of composites of topaz-glass as TSEE and TL dosemeters.

The properties of the thermally stimulated exoelectron emission (TSEE) and thermoluminescent (TL) emission of topaz-glass composites were studied with the aim of using them as solid-state dosemeters. The TSEE response was studied as a function of radiation energy and as a function of absorbed dose. Topaz-glass composites presented a linear TL and TSEE response to dose within a range of 0.01-1 G...

متن کامل

Photo- and Thermally Stimulated Relaxation Processes in Pre-irradiated Atomic Solids

1 Institute for Low Temperature Physics and Engineering of the NASU, Lenin Ave. 47, Kharkov 61103, Ukraine 2 Institute of Physical and Theoretical Chemistry, TU Munich, Lichtenbergstr. 4, Garching 85747, Germany 3 Fritz-Haber-Institut der Max-Plank-Gesellschaft, Department of Molecular Physics, Berlin14195, Germany ________________________________________________________________________ Abstrac...

متن کامل

DIRECT LUMINESCENCE AND THERMALLY STIMULATED LUMINESCENCE OF 4H CdI2

Direct luminescence (DL) spectra of 4H Cd12 in the spectral region 1.8-3.4 eV at temperatures between 9.3 and 215 K and thermally stimulated luminescence (TSL) spectra are reported. The DL spectra consist of several overlapping broad emission bands. These bands are due to radiative recombination of localized (trapped) electrons with localized (trapped) holes. With a simple theory, which takes i...

متن کامل

Application of spectroscopic techniques in the radiation dosimetry of glasses: An update

The colorimetry and thermoluminescence properties of gamma irradiated glass were reported in as early as 1920. The utility of radio-photoluminescence (RPL) of silver activated metaphosphate glass for monitoring high doses of accidental and routine gamma radiation was reported in the 1960s. Since then considerable amount of research work has been carried out to study the thermoluminescence (TL),...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

دوره 64 8  شماره 

صفحات  -

تاریخ انتشار 2006