A Review of Mg Isotope Analytical Methods by MC-ICP-MS

نویسندگان

  • Yajun An
  • Fang Huang
چکیده

Application of multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) has led to big breakthrough of analytical methods for metal stable isotopes, resulting in rapid progresses in non-traditional stable isotope geochemistry. As a new geological tracer, Mg isotopes have been widely applied in studies of almost all important disciplines of geochemistry. High precision Mg isotope data measured by MC-ICP-MS are now available with precision about 0.05‰ amu (2SD) or better. Because mass bias caused by chemical procedure and instrument can easily cause significant analytical error, it is still a challenge to obtain accurate Mg isotope data for natural samples. In this paper, we systematically review the development of analytical technique of Mg isotopes, with a detailed description of a series of important techniques used in the measurement process, including calibration of instrumental mass-bias, chemical purification process, matrix effect, and pitfalls for high precision isotope analyses. We compare standard data from different labs and establish a guideline for Mg isotope analysis procedure. Additionally, we briefly discuss the behaviors of Mg isotopes during geological processes including equilibrium and kinetic Mg isotope fractionations, such as magma differentiation, chemical and thermal diffusion, and continental weathering. Finally, we propose some future prospects for Mg isotope geochemistry in both high and low temperature geological processes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selected isotope ratio measurements of light metallic elements (Li, Mg, Ca, and Cu) by multiple collector ICP-MS

The unique capabilities of multiple collector inductively coupled mass spectrometry (MC-ICP-MS) for high precision isotope ratio measurements in light elements as Li, Mg, Ca, and Cu are reviewed in this paper. These elements have been intensively studied at the Geological Survey of Israel (GSI) and other laboratories over the past few years, and the methods used to obtain high precision isotope...

متن کامل

The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements†

The performance and validation characteristics of different single collector inductively coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP-QMS in reaction and collision modes, and ICP-MS/MS) were evaluated in comparison to the performance of MC ICP-MS for fast and reliable S isotope ratio measurements. The validation included the determination of LOD, BEC,...

متن کامل

Magnesium isotopic composition of igneous rock standards measured by MC-ICP-MS

Keyword: Mg isotopes Igneous rock standards MC-ICP-MS To provide inter-lab comparison for high-precision Mg isotope analysis, Mg isotope compositions (expressed as δMg relative to DSM-3) for commercially accessible peridotite, basalt, andesite, and granite geostandards have been measured by multi-collector inductively coupled mass-spectrometry (Nu-Plasma) using sample-standard bracketing method...

متن کامل

Strontium isotope ratios (87Sr/86Sr) of tooth enamel: a comparison of solution and laser ablation multicollector inductively coupled plasma mass spectrometry methods.

Strontium isotope ratios (87Sr/86Sr) in tooth enamel provide a means to investigate migration and landscape use in humans and other animals. Established methods for measuring (87)Sr/(86)Sr in teeth use bulk sampling (5-20 mg) and labor-intensive elemental purification procedures before analysis by either thermal ionization mass spectrometry (TIMS) or multicollector inductively coupled plasma ma...

متن کامل

Mass independent bias in W isotopes in MC-ICP-MS instruments

The determination of natural mass independent isotope variations by precise isotopic measurements of elements by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) requires a detailed understanding of the instrumental mass bias. Until recently, the instrumental mass bias in MC-ICP-MS analysis was considered to be entirely mass dependent, most often corrected by an exponent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014