Using Total Hip Prosthesis with Porous-Coated and Interlocking System In Twenty-one Dogs

نویسندگان

  • Serhat ÖZSOY
  • Zihni MUTLU
  • Dilek Olgun
  • Kemal ALTUNATMAZ
چکیده

In this study, porous-coated, fixed with screwed-system femoral prosthesis and total hip prosthesis composed of screwed-system acetabular cup were applied on 21 dogs of different breeds, sexes and ages. Total hip arthroplasty (THA) was applied as one sided in all cases. In 7 cases luxation occured and in 5 of them the prostheses were taken out. One of the cases had a second operation for dislocation, but because of reluxation the prosthesis was taken out again. Ventral luxation occured in one of the cases but with a second operation success was obtained. Aseptic loosening of the femoral implant occured in 1 case, and in 1 case aseptic loosening of acetabular cup occured, both prostheses were taken out. One case died due to another disease. It has been indicated that the 12 cases are going on their livings with the applied prostheses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-Term Results of Total Hip Arthroplasty with an Extensively Porous Coated Stem in Patients Younger than 45 Years Old

PURPOSE This study analyzed the long-term results of cementless total hip arthroplasty using an extensively porous coated stem in patients younger than 45 years old. MATERIALS AND METHODS The clinical and radiographic results of 45 hips from 38 patients who underwent cementless total hip replacement arthroplasty with an AML prosthesis were reviewed retrospectively. The average follow-up was 1...

متن کامل

Modular hybrid total hip arthroplasty. Experimental study in dogs

BACKGROUND This prospective experimental study evaluated the surgical procedure and results of modular hybrid total hip arthroplasty in dogs. METHODS Ten skeletally mature healthy mongrel dogs with weights varying between 19 and 27 kg were used. Cemented modular femoral stems and uncemented porous-coated acetabular cups were employed. Clinical and radiographic evaluations were performed befor...

متن کامل

Bone density study of the proximal femur after hip arthroplasty with porous-coated implants

Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...

متن کامل

Twenty-year survival of a cementless revision hip arthroplasty using a press-fit bulk acetabular allograft for pelvic discontinuity: a case report.

Acetabular revision in a total hip arthroplasty (THA) with pelvic discontinuity is uncommon and challenging. Optimal management remains controversial, particularly with graft and implant selection. Interpretation of outcomes is confounded by the heterogeneity of patterns of bone loss and the lack of long-term results in great numbers for any given choice of treatment. We report a revision THA u...

متن کامل

Cementless total hip arthroplasty using the omnifit system: An 8.2 year follow-up study of 166 hips.

One hundred and sixty-six cementless primary total hip arthroplasties were performed in 133 patients with porous coated Omnifit prosthesis. The average age was 49.7 years. The mean follow-up period was 8.2 years with a minimum of 5 years. Good to excellent clinical results were achieved in 93% of patients. The overall revision rate was 5.4%. Radiographically, bone ingrowth occurred in all unrev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011