A comparison of the effectiveness of intubation using a McGrath Series 5 videolaryngoscope with either a Truflex articulating stylet or a standard intubation stylet in a group of medical students

نویسنده

  • TOMASZ GASZYŃSKI
چکیده

Background. Intubation is the optimal method for opening the airway and effective ventilation of the patient. However, there are occasional problems with intubation, especially in patients with injuries under pre-hospital conditions. Therefore, it is important to identify devices, e.g., videolaryngoscopes or guides, which may facilitate and shorten the procedure. This study addresses the use of a Truflex articulated guide with a videolaryngoscope. Objectives. The main objective of the study is to evaluate the effectiveness of intubation using a Truflex articulating stylet with a McGrath videolaryngoscope, and to determine whether the average time of intubation using a Truflex articulating stylet is shorter than that using a standard intubation stylet. Materials and methods. The study involved 43 full-time 5th year medical students. All tests were performed on training manikins with a difficult airway in January 2013. Chi-square test was used for statistical analysis with a significance level of p SIGNA VITAE 2015; 10(1): 127 135

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Tracheal Intubation Using the Storz’s C-Mac D-bladeTM Video-Laryngoscope Aided by TruflexTM Articulating Stylet and the PortexTM Intubating Stylet

BACKGROUND Tracheal intubation using Storz's C-Mac D-blade(TM) videolaryngoscope is associated with difficult negotiation of the tracheal tube into the glottis due to steep angulation of its blade. OBJECTIVES In this study, we hypothesized that Truflex(TM) articulating stylet with its ability to dynamically tailor the ETT shape to patients' oropharyngeal anatomy would be better suited to the ...

متن کامل

Assessment of Truflex™ articulating stylet versus conventional rigid Portex™ stylet as an intubation guide with the D-blade of C-Mac™ videolaryngoscope during elective tracheal intubation: study protocol for a randomized controlled trial

BACKGROUND A variety of videolaryngoscopes with angulated blade have been recently introduced into clinical practice. They provide an indirect view of the glottic structures in normal and challenging clinical settings. Despite the very good visualization of the laryngeal structures by these devices, the insertion and advancement of the endotracheal tube may be prolonged and occasionally fail as...

متن کامل

Stylet angulation for routine endotracheal intubation with McGrath videolaryngoscope

BACKGROUND The McGrath videolaryngoscope (VL) provides excellent laryngoscopic views, but directing an endotracheal tube can be difficult, and thus the routine use of a stylet is recommended. The goal of this study is to determine the appropriate angle (60° vs 90°) of the stylet when using the McGrath VL by comparing the time to intubation (TTI). METHODS One hundred and forty patients aged 19...

متن کامل

Intubation without use of stylet for McGrath videolaryngoscopy in patients with expected normal airway

BACKGROUND During McGrath videolaryngoscope (VL) intubation, a styletted endotracheal tube maintaining an upward distal tip angle is recommended by some manufacturers. However, a styletted endotracheal tube can elicit rare but potentially serious complications. The purpose of this study was to demonstrate that a nonstyletted tube with exaggerated curvature would be noninferior to a styletted tu...

متن کامل

[Comparison of different stylets used for intubation with the C-MAC D-Blade® Videolaryngoscope: a randomized controlled study].

OBJECTIVE The angle of the C-MAC D-Blade® videolaryngoscope, which is used for difficult airway interventions, is not compatible with routinely used endotracheal tubes. METHODS A prospective randomized crossover study was performed comparing five intubation methods for use with standardized airways, including using different stylets or no stylet: Group HS, hockey-stick stylet; Group DS, D-bla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015