Measurement of Calcium Activity in Oral Fluids by Ion Selective Electrode: Method Evaluation and Simplified Calculation of Ion Activity Products
نویسندگان
چکیده
The activity of calcium in plaque fluid is needed to calculate the saturation level of that fluid relative to the tooth mineral. One method to determine the calcium activity in very small plaque fluid samples is by micro ion-selective electrode (ISE). Two commercially available calcium ionophores, a neutral-carrier and a charged-carrier, were evaluated in micro ISEs and compared to a commercially available macro ISE using saliva as a model for plaque fluid. The neutral-carrier containing ISEs gave results consistent with those of the macro ISE. Calcium activity measurements made with micro ISEs that contained the neutral ion-carrier of whole plaque samples and plaque fluid samples obtained by centrifugation of whole plaque showed that the activities did not change due to centrifugation. Estimates of the saturation with respect to hydroxyapatite were made from these measurements. A simplified calculation method is presented to estimate the ion activity product (IAP) of the calcium-phosphate minerals. The method is based on the relative abundance of some of the possible calcium-binding species and a fixed ionic strength for plaque fluid. Calculations show that within a normal pH range for plaque fluid (5.0 to 7.5) the differences in the IAP calculations for hydroxyapatite using the simplified method are less than those estimated from propagation of uncertainty calculations.
منابع مشابه
Measurement and Modeling of Mean Ionic Activity Coefficient in Aqueous Solution Containing NaNO3 and Poly Ethylene Glycol
Potentiometric investigation on {H2O+NaNO3+PEG1500} mixtures were made at T=308.15K, using electrochemical cells with two ion-selective electrodes, (Na+ glass) as the cation ion-selective electrode against (NO3- solvent-polymer PVC) as the anion ion-selective electrode. The mean ionic activity coefficients of NaNO3 were measu...
متن کاملDesign and Fabrication of PVC Membrane Electrode Based on Netural Ligand (E)-N'-(1-(2-Hydroxyphenyl)Ethylidene)Benzohydrazi for Teramadol hydrochloride Measurement in Drugs and Biological Fluids
Here, a simple, quick, Low cost and sensitive Potentiometric method is described for tramadol hydrochloride measurement using .PVC membrane electrode based on neutral ligand (E)-N'-(1-(2-hydroxyphenyl)ethylidene)benzohydrazid. Besides, effect of various parameters like ionic additives, membrane solvent and pH on the Potentiometric response of the electrode are investigated. The best electrode p...
متن کاملConstruction of S?-Selective Electrode and Thermodynamic Study of the Ternary Aqueous Mixed Electrolyte System (SrCl2, KG, H20) Using Potentiometric Method
In order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (NPDBH) was used as an ionophore. This electrode responds to Sr (II)ion with a sensitivity of 28.2 ± 0.5 mV/decade over the range 1.0 x 10-6 to 1.0 Mat pH 3.0-10.0. Thelimit of detection was 2.4 x 10-7 M. The influences of membrane composition, the pH of the t...
متن کاملSpectrophotometric determination of Dalacin phosphate from formulations using reduce atomic absorption of calcium ion by phosphate
A simple, sensitive and accurate method for spectrophotometric determination of Dalacinphosphatehas been established. The method is based on the reduction of atomic absorptioncalcium ion by phosphate. Because, there is a phosphate mole in every Dalacin mole structureand with measurement of phosphate, Dalacin is beyond measurement too. Therefore, the reactionbetween acidic hydrolysis products of...
متن کاملConstruction of Cu2+-selective electrode and thermodynamic study of the ternary aqueous mixed electrolyte system (CuCl2, KCl, H2O) using nanocomposite-based potentiometric sensor
A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...
متن کامل