New device for saphenous vein-to-aorta proximal anastomosis without side-clamping

نویسنده

  • Ernesto Tappainer
چکیده

BACKGROUND Side clamping to perform saphenous vein-to-aorta proximal anastomosis is a well known cause of cerebral embolization during coronary bypass surgery. Automatic and manual devices have been introduced to avoid aortic clamping and facilitate proximal anastomosis but the manual ones only allow the traditional hand-sewing running suture. Nevertheless, they are not easy to use and very expensive to buy. METHODS We developed a simple object that helps to perform a manual proximal anastomosis without the need to clamp the side of the aorta. This device is a steel bar which blocks the aortic hole and simultaneously it provides a slit to receive the needle. Through the slit comes out a thin, sharp, straight, but also well directed and predictable jet of blood which could be easily controlled during the suture. RESULTS The function of the object is quite different from other devices. Nothing is deployed in the aorta. The object is only placed on the aorta with the small appendage slipped into the hole. The main advantage of the device is that while manipulation of the aorta is avoided no foreign bodies are incorporated in the suture and - most importantly - the aortic intima is not touched at all. The main drawback of the device is the blood jet coming from the slit so that the blood pressure has to be lowered by vasodilators during the anastomosis. Moreover, the suture has to change direction and the needle has to enter the aortic wall first to slip out through the slit. CONCLUSION The object was named "Slit Device" and is not a routine instrument. It would be only an alternative to other anastomotic devices with the same surgical indications. In the case of ascending aortic disease and saphenous vein grafting, the Slit Device avoids aortic clamping thereby preventing atheroembolism and also avoiding the need for hypothermic circulatory arrest in patients with unclampable aorta.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dikmengil Technique for Proximal Anastomosis of Saphenous Vein to Aorta Using Hegar Dilator Without Clamping

Manipulation of aorta, such as side clamping of the ascending aorta, is known as a possible cause of the increased incidence of perioperative cerebrovascular accidents during myocardial revascularization. We describe an easy and cheap alternative technique for proximal anastomosis of saphenous vein to aorta using a Hegar dilator without clamping in off-pump coronary artery bypass procedures. IN...

متن کامل

Vettath's anastomotic obturator: a simple proximal anastomotic device.

BACKGROUND Off-pump coronary artery bypass grafting has been shown to improve the postoperative course of patients undergoing coronary artery bypass grafting (CABG) surgery, but the need for side-clamping the aorta to perform the proximal anastomosis is still a risk factor for causing neurologic injury postoperatively. Hence, our endeavor to fabricate an obturator to perform the proximal anasto...

متن کامل

A case of ostial stenosis with the PAS-Port proximal anastomosis system in off-pump coronary artery bypass grafting.

The use of an automatic aortic connector device for proximal saphenous vein graft anastomoses eliminates the need for aortic clamping during off-pump coronary artery bypass grafting and may reduce the incidence of stroke in the elderly and in patients with severe aortic atherosclerosis. The PAS-Port proximal anastomotic system is a recently developed sutureless automatic saphenous vein graft an...

متن کامل

Hand-Sewn Proximal Anastomoses in Off-Pump Coronary Artery Bypass Without the Need for Partial Occlusion Clamping: Experience With the Heartstring II Proximal Seal System.

OBJECTIVE : To evaluate the use of the Heartstring II Proximal Seal System (HPSS) in saphenous vein to aorta anastomoses in off-pump coronary artery bypass (OPCAB). METHODS : The HPSS consists of an aortic cutter and a proximal seal system. A prospective study was done using the HPSS to facilitate proximal hand-sewn anastomoses in OPCAB without partial occlusion clamping. Intraoperative obser...

متن کامل

Initial experience with proximal anastomoses performed with a mechanical connector.

BACKGROUND The Symmetry Bypass System Aortic Connector (St Jude Medical, Inc) is a novel device for the construction of sutureless proximal anastomoses. The connector allows attachment of saphenous vein grafts to the aorta without requiring aortic clamping. We report our initial clinical experience with this device. METHODS In a 2-month period from May to July 2001, a total of 139 consecutive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Cardiothoracic Surgery

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2007