Atomic mass of Li using a Penning-ion-trap mass spectrometer

نویسندگان

  • T. P. Heavner
  • S. R. Jefferts
  • G. H. Dunn
چکیده

The atomic mass of Li has been measured using a Penning-ion-trap mass spectrometer to be 6.015 122 795~16! u. The fractional measurement uncertainty of 62.7310 represents a 30-fold improvement over that of the accepted published value. External ion sources were used to create ions outside the cryogenic ~4 K! environment of the Penning trap and an ion-transport beamline was used to deliver ions into the trap for measurement. The ion mass ratios of Li:C and Li:D3 1 were measured using this apparatus and the atomic mass of neutral Li was derived from these ratios. A measurement of the He:D2 1 mass ratio with a fractional uncertainty of 61.1310 and differing from the accepted published value by a fractional amount 20.6310 is also reported.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Position-sensitive ion detection in precision Penning trap mass spectrometry

A commercial, position-sensitive ion detector was used for the rst time for the time-ofight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its implementation in a Penning trap mass spectrometer will be presented. In addition, simulations and experimental studies concerning the observation of ions ejected from ...

متن کامل

EUROPEAN ORGANISATION FOR NUCLEAR RESEARCH Ramsey Technique Applied in a Penning Trap Mass Spectrometer

The Ramsey method has been applied in an experiment aiming for accurate mass determination of unstable isotopes. The ion motion in a Penning trap has been excited with time-separated oscillatory elds and Ramsey fringes were observed in the case of dipole and quadrupole excitation. The experimental resonances are in good agreement with theory. Further applications of the technique are discussed....

متن کامل

Electron Capture Dissociation in a tiny Penning Trap coupled with a Linear Radio-Frequency-Quadrupole Ion Trap – Time-of-Flight Mass Spectrometer

Introduction: We report a theoretical study of Electron Capture Dissociation (or ECD) in a Penning trap and a novel bench top instrument for ECD. ECD is recognized as a useful technique for peptide/protein analysis because it provides adiabatically cleaved fragment information (C and Z fragments) that are difficult to obtain by widely used methods such as Collision Induced Dissociation and Infr...

متن کامل

Ramsey method of separated oscillatory fields for high-precision penning trap mass spectrometry.

Ramsey's method of separated oscillatory fields is applied to the excitation of the cyclotron motion of short-lived ions in a Penning trap to improve the precision of their measured mass values. The theoretical description of the extracted ion-cyclotron-resonance line shape is derived and its correctness demonstrated experimentally by measuring the mass of the short-lived 38Ca nuclide with an u...

متن کامل

Study of ground- and low-lying nuclear states by combining laser ionization and Penning trap mass spectrometry

The combination of resonant laser ionization, nuclear spectroscopy and mass measurements allows the deconvolution of the low-energy structure of atomic nuclei. Three β-decaying isomers of Cu have been unambiguously identified with the Penning trap mass spectrometer ISOLTRAP. In addition, isomerically pure ensembles of the short-lived radionuclides Cu have been prepared.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001