Observations and Considerations on Patient X-ray Exposure in the Electrophysiology Lab.

نویسندگان

  • Xianxian Jiang
  • Lukas Rc Dekker
چکیده

To assess patient radiation during catheter ablation procedures and operator differences. From 84 patients (51 males, age 63 ± 10 years) undergoing complex catheter ablation by three experienced operators we collected: body mass index (BMI), procedure type and time, fluoroscopy time, dose area product (DAP), air kerma and X-ray system setting (cine, collimation and angiographic imaging angle). A new factor, fluoroscopy DAP-fluoroscopy time ratio, was introduced to compare operator differences. The results show the average procedure time was 179 (± 57) minutes (min), fluoroscopy time was 31 (± 21) min, DAP was 26.4 (± 19.6) Gy.cm(2) and air kerma was 0.26 (± 0.19) Gy. Procedure types were: pulmonary vein isolation (PVI) (52 %), redo PVI (11 %), pulmonary vein ablation catheter (PVAC) (14 %), ventricular tachycardia (VT) (8 %) and others (15 %). Inter-operator difference was observed in fluoroscopy and cine usage. Fluoroscopy DAP-time ratios showed a similar level of patient radiation dose rate by operator A and B (correlation: 0.89), and a significantly higher dose rate by operator C (correlation: 0.20, p<0.001; 0.26, p<0.01, to operator A and B). In conclusion, operators should be aware of patient radiation exposure levels and the influencing factors. Inter- and intra-operator differences can be measured and bench marked for improvement in X-ray efficiency and patient radiation reduction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Evaluation of Conventional X-ray Exposure Parameters Including Tube Voltage and Exposure Time in Private and Governmental Hospitals of Lorestan Province, Iran

Introduction In radiography, dose and image quality are dependent on radiographic parameters. The problem is caused from incorrect use of radiography equipment and from the radiation exposure to patients much more than required. Therefore, the aim of this study was to implement a quality-control program to detect changes in exposure parameters, which may affect diagnosis or patient radiation do...

متن کامل

Evaluation of Patient's Dose and Estimate of Cancer Risk in Electrophysiology Studies and Ablation in Cath Lab Center of Afshar Hospital, Yazd, Iran

Introduction: Today electrophysiology studies and ablation have been developed due to increasing arrhythmias disorder of heart. In these diagnostic – treatments methods, the use of fluoroscopy can be causes patient radiation dose, therefore evaluation of patient's absorbed dose is necessary to protection of the radiation. The aim of this study was to evaluate the absorbed dose in patients under...

متن کامل

Patient dose in routine X-ray examinations in Yazd state

Background: Medical x-rays are the largest man-made source of public exposure to ionizing radiation. It is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. Materials and Methods: The Entrance Skin Exposure (ESE) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. The ESEs we...

متن کامل

Quality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran

Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the da...

متن کامل

The Effect of Long-Term X-Ray Exposure on Human Lymphocyte

The aim of the paper is to investigate effects of long term x-ray exposure on the human lymphocyte, reactive lymphocyte parameters and morphology of lymphocytes in x-ray technicians at Kirkuk hospitals. The study included 54 apparently healthy male x-ray technicians were matched with another 54 apparently healthy control to show any alteration in the lymphocytes, reactive lymphocytes and morpho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arrhythmia & electrophysiology review

دوره 2 2  شماره 

صفحات  -

تاریخ انتشار 2013