Modeling and measurement of the variations of CT number distributions for mobile targets in cone‐beam computed tomographic imaging
نویسندگان
چکیده
The purpose of this study was to investigate quantitatively by measurement and modeling the variations in CT number distributions of mobile targets in cone-beam CT (CBCT) imaging. CBCT images were acquired for three targets manufactured from homogenous water-equivalent gel that was inserted into a commercial mobile thorax phantom. The phantom moved with a controlled cyclic motion in one-dimension along the superior-inferior direction to simulate patient respiratory motion. Profiles of the CT number distributions of the static and mobile targets were obtained using CBCT images. A mathematical model was developed that predicted the variations in CT number distributions and their dependence on the motion parameters of targets moving in one-dimension using CBCT imaging. The measured CT number distributions for the mobile targets varied considerably, depending on the motion parameters. The extension of the CT number distribution increased linearly with motion amplitude where maximum target elongation reached twice the motion amplitude. The CT number levels of the mobile targets were smeared over a longer distribution; for example, the CT number level for the 20 mm target dropped by nearly 30% at motion amplitude (A) equal to 20 mm in comparison with the CT number distribution of stationary targets. Frequency of motion played an important role in spatial and level variations of the CT number distributions. For example, the level of the CT number profile for the medium target (20 mm) decreased evenly by nearly 50% at A = 20 mm with high motion frequencies. Motion phase did not affect the CT number distributions for prolonged projection acquisition that included several respiratory cycles. The mathematical model of the CT number distributions of mobile targets in CBCT reproduced well the measured CT number distributions and predicted their dependence on the target size and phantom motion parameters such as speed, amplitude, frequency, and phase. The CT number distributions varied considerably with motion in CBCT. A motion model of CT number distribution for mobile targets has been developed in this work that predicted well the variations in the measured CT number profiles and their dependence on motion parameters. The model corrected the CT number distribution retrospective to CT image reconstruction where it used a first-order linear relationship between the number of projections collected in the imaging window of a mobile voxel to obtain the cumulative CT number. This model provides quantitative characterization of motion artifacts on CT number distributions in CBCT that is useful to determine the validity of CT numbers and the accuracy of localization and volume measurement of tumors in diagnostic imaging and interventional applications, such as radiotherapy.
منابع مشابه
Evaluation of the Association of Sinus Mucosal Thickening with Dental and Periodontal Status Using Cone Beam Computed Tomographic Imaging
Introdouction: Cone Beam Computed Tomography (CBCT) is a relatively new three-dimensional imaging technology, which has been widely used in dental and maxillofacial imaging. Materials and methods: CBCT scans of 506 maxillary sinuses of 253 individuals (39.9% male and 60.1% female) were evaluated retrospectively for assessing the relationship between sinus mucosal thickening (MT) and dental a...
متن کاملQuantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging
The purpose of this study was to assess quantitatively elongation of mobile targets in cone-beam CT (CBCT) imaging by measurement and modeling. A mathematical model was derived that predicts the measured lengths of mobile targets and its dependence on target size and motion patterns in CBCT imaging. Three tissue-equivalent targets of differing sizes were inserted in an artificial thorax phantom...
متن کاملThe Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography
Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملA feasibility study on the use of MV-CBCT images for urgent palliative treatment planning
Introduction: The application of 3D volumetric imaging modalities in treatment planning of radiation therapy can provide more precisely define tumor localization, and computed tomography (CT) is the most common accepted method for treatment planning. Given the lack of a CT scanner stationed in all radiotherapy departments and equipping most of the medical linear accelerators wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -