A Langmuir probe system incorporating the Boyd - Twiddy method for EEDF measurement applied to an inductively coupled plasma source

نویسندگان

  • B Crowley
  • S Dietrich
چکیده

This paper reports on a modern implementation of a Langmuir probe method that was first proposed in the 1950’s. The system directly measures the first and second derivative of the I-V characteristic and determines the EEDF. This probe offers many advantages over existing systems that rely on numerical differentiating and data smoothing techniques. In addition to the EEDF analysis the system also incorporates several theories to extricate the plasma parameters from the ion collection and electron retardation branches of the I-V characteristic.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of electron temperatures of Argon Plasmas in a High-Density Inductively-Coupled Remote Plasma System by Langmuir Probe and Optical-Emission Spectroscopy

We measured electron density and electron energy distribution function (EEDF) in our reactor by a Langmuir probe. The EEDF of Ar plasma in the reactor could largely be described by the Maxwell-Boltzmann distribution function, but it also contained a fraction (~10) of electrons which were much faster (20-40 eV). The peak of the fast-electron tail shifted from E ~ 35 eV at 11 μbar to E ~ 25 eV wh...

متن کامل

Origin of Electrical Signals for Plasma Etching Endpoint Detection

To investigate the electrical changes observed at plasma etching endpoints, experiments were performed in an inductively coupled, rf-biased reactor, during CF4/Ar plasma etches of silicon dioxide films on silicon substrates. The rf bias current, voltage, and impedance were measured vs. time during etching. Simultaneously, a Langmuir probe measured the electron and ion densities, ion current den...

متن کامل

Double Langmuir probe measurement of plasma parameters in a dc glow discharge

In this paper, plasma main characteristics such as electron mean temperature, electron number density, and oscillation frequency have been measured experimentally using the double Langmuir probe diagnostic system. In our experiment, the plasma was generated by applying the low pressure dc glow discharge in several common gases. The experimental results indicated the highest plasma density and o...

متن کامل

Langmuir Probe Measurements in the Gaseous Electronics Conference RF Reference Cell

The use of a Langmuir probe system in two GEC cells is reviewed. The major problems associated with probe diagnostics in a GEC cell are outlined and discussed. While the data base is still insufficient to give definitive values for many parameters, a number of standard measurements are put forward. The plasma density in argon is 9×109 cm-3 (±20 %) at an applied rf voltage of 250 V (500 V peak t...

متن کامل

Influence of O2 and N2 Concentrations on the Characteristics of Plasma in DC Cylindrical Magnetron Discharge by Langmuir Probe

Using the Langmuir probe method, the reactive plasma parameters were studied in different ratios of oxygen and nitrogen concentrations in a DC cylindrical discharge device.The plasma parameters such as plasma potential, electron density and electron temperature wereextracted from the current-voltage characteristic’s curve of Langmuir probe to find the optimum conditions for deposit the oxy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008