SU-E-T-103: Three-Dimensional Measurements of Dose and LET from a Proton Beam via Polymer Gel Dosimetry.

نویسندگان

  • K Vredevoogd
  • G Ibbott
  • M Gillin
  • N Sahoo
  • S Kry
  • K Gifford
  • M Maryanski
چکیده

PURPOSE To obtain and assess the accuracy of 3D dose distributions and LET maps from a passively-scattered proton beam through the use of LET-dependent and LET-independent polymer gel formulations. METHODS Dose measurements were performed with BANG3-Pro2 (MGS Research, Inc, Madison, CT) polymer gel dosimeters. The dosimeters were mixed from kits and were poured into 14.5 cm high by 15 cm diameter acrylic cylinders. For LET measurements, a new BANG3-Pro variant intended for use as an 'LET- meter' was employed. Initial irradiations were performed using a 200 MeV passively scattered proton beam with a 4 cm spread out Bragg peak (SOBP), delivering a physical dose of 3 Gy to the center of the SOBP. Dosimeters were read out using the OCTOPUS-IQ (MGS Research, Inc, Madison, CT) optical CT scanner. The optical densities measured in the gel were compared against ion chamber data to assess the accuracy of the dosimeter. RESULTS Initial analysis indicates 80% of points measured along the central axis agreed with ion chamber data at the ±5%/±3mm level in the sensitive region of the gel. An artifact in the reconstructed image produced inaccurate readings beyond the depth of 50% dose on the distal edge of the SOBP, resulting in the majority of the agreement failures. CONCLUSIONS BANG3-Pro2 polymer gel dosimeters demonstrate promise as a 3D dosimeter for use in proton therapy. The dosimetric data obtained to date will be used as the baseline measurement against which the LET-sensitive BANG3-Pro formulation will be compared for the measurement of proton LET.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of MRI-based Polymer Gel Dosimetry for Measurement of CT Dose Index (CTDI) on 64 slices CT Scanners

Introduction: Computed tomography (CT) has numerous applications in clinical procedures but its main problem is its high radiation dose to the patients compared to other imaging modalities using x-ray. CT delivers approximately high doses to the nearby tissues due to the scattering effect, fan beam (beam divergence) and limited collimator efficiency. The radiation dose from multi-slice scanners...

متن کامل

Gel dosimetry: The effect of gold nanoparticles on the dose enhancement in the external radiation therapy

Background: Normoxic type MAGICA gel dosimeters are established for dose quantification in three dimensions for radiotherapy. Objective(s): The ability of MAGICA polymer gel was assessed by experimental measurements method for studying the effect of gold nanoparticles (GNPs) in dose enhancement under the external 18MV radiotherapy practices. <...

متن کامل

Three-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT

Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...

متن کامل

Dosimetric Evaluation of Linac Photon Small Fields using MAGIC Polymer Gels

Introduction: In radiotherapy, methods of treatment planning are becoming increasingly more complicated. This requires verification of the doses delivered to increasingly smaller and more precise regions. Radiotherapy techniques are continuously employing smaller and smaller field sizes to deliver tighter radiation doses with higher therapeutic ratios, generating interest among researchers to p...

متن کامل

An Investigation of the Dose Distribution from LDR Ir-192 Wires in the Triangular Implants of the Paris System using Polymer Gel Dosimetry

Introduction: Polymer gels are modern dosimeters providing three dimensional dose distributions. These dosimeters can be used in brachytherapy in which the tumor dimension is relatively small and the dose gradient is high. In this study, the ability of the MAGICA polymer gel was investigated for assessing the absolute dose values as well as the dose distribution of low dose rate (LDR) Ir-192 wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part11  شماره 

صفحات  -

تاریخ انتشار 2012