Faraday shields within a solenoidal coil to reduce sample heating: numerical comparison of designs and experimental verification.
نویسندگان
چکیده
A comparison of methods to decrease RF power dissipation and related heating in conductive samples using passive conductors surrounding a sample in a solenoid coil is presented. Full-Maxwell finite difference time domain numerical calculations were performed to evaluate the effect of the passive conductors by calculating conservative and magnetically-induced electric field and magnetic field distributions. To validate the simulation method, experimental measurements of temperature increase were conducted using a solenoidal coil (diameter 3 mm), a saline sample (10 mM NaCl) and passive copper shielding wires (50 microm diameter). The temperature increase was 58% lower with the copper wires present for several different input powers to the coil. This was in good agreement with simulation for the same geometry, which indicated 57% lower power dissipated in the sample with conductors present. Simulations indicate that some designs should be capable of reducing temperature increase by more than 85%.
منابع مشابه
Natural Convection from a Helical Heating Coil to the Surrounding Fluid.
An experimental study is reported on natural convection heat transfer from a helical heating coil to the surrounding fluid. The coil is heated electrically and the surrounding fluid is selected to be water. The range of parameters are: Rayleigh number, 879 ?£ Ra ?£ 780168, Prandtl number, 4.22 ?£ Pr ?£ 10.02, dimensionless coil diameter,7.69 ?£ Dave /d ?£ 10.77, number of coil rings, 2 ?£ N ?£ ...
متن کاملمطالعه عددی تأثیر تعداد حلقههای پیچه برگرمای تولید شده در فرایندگرمای القایی در مدل سهبعدی
Computer modeling for the design of inductors for different applications in the induction heating process often seems to be necessary to save costs caused by the trial and error. In this paper, the effects of the number of loops in the induction heating process with the numerical solution of the Maxwell equations have been investigated using finite element method (FEM) and the COMSOL MULTIPHYSI...
متن کاملA New Restructured Shaded Pole Induction Motor- 3D Finite Element Analysis and Experimental Verification
Shaded pole induction motors, despite the simplicity and low cost, are difficult to analyze particularly in the equivalent circuit methods, due to the asymmetric structure, saturation, harmonics, inaccurate estimation of leakage inductances and skew. Hence, 3D numerical methods could be very useful in the design and optimization stage. This paper presents the 3D transient finite element analysi...
متن کاملLow power field generation for magneto-optic fiber-based interferometric switches
A new fiber-based, magneto-optic switch is proposed with a novel approach for low power and efficient operation. The switch, with reasonable switching speed compared to competitive designs, operates at considerably reduced power levels, which makes it a practical deployable solution. The basic switch setup consists of a Faraday rotator in a Sagnac fiber-optic interferometer in which optical swi...
متن کاملExperimental Temperature and Specific Absorption Rate Mapping Using MRI in a Transmit-receive Head Coil at 3.0T
Introduction: MRI-based temperature mapping techniques have been applied to detect the temperature changes (∆T ) for a variety of applications, including during the thermoablation of tumors [1], and in verifying minimal temperature increment induced by EEG electrodes and/or its wires during MRI [2]. Although numerical calculations have been used to predict SAR distributions and resulting temper...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance
دوره 202 1 شماره
صفحات -
تاریخ انتشار 2010