Method to Minimize the Clock Skew and Uniform Clock Distribution using Parallel Port in Pipe Line Based Multi Channel DMA Request Terminal for Frequency Measurement

نویسنده

  • Suresh Kumar
چکیده

This paper presents a new wide-range digital speed measurement method with jitter removal technique and using the direct memory access (DMA) terminal count register (TCR). Our work also supports a multi node interfacing from different measure ends. The multiple measure ends are interfaced with DMA channels through pipelines to improve hit ratio. Here hit ratio indicates the exact identification of encoder pulses without any fail or miss. But the conventional pipeline system is facing problems due to improper synchronization of clock pulses. This is a universal problem in all the digital systems mostly called jitter or skew. Here a new system is implemented in the path of the clock to remove or reduce the clock skew. The jitter is also introduced in the pipeline due to different clock paths to the parallel pipelines. While one pipeline access the encoder pulses the remaining pipelines remain in idle state as single clock pulse is used to fed encoder pulses. And it creates a big challenge if multiple clock pulses are given to individual pipeline systems. This can be overcome using parallel ports as clock signals. The DMA method is based on both pulses counting in the constant sampling time at terminal count stop pin of a DMA controller. The hardware configuration and algorithms for a microcontroller implementation are also presented. The proposed method is suitable in systems using microcontrollers with DMA controller and timers. Limitations and sources of errors are discussed in details. The DMA Terminal count register method is suitable for real-time speed control systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Over GHz Low-Power RF Clock Distribution For a Multiprocessor Digital System

Conventional digital clock distribution interconnection causes a severe power consumption problem for GHz clock distribution because of transmission line losses, and it exhibits difficult signal integrity problems due to clock skew, clock jitter and signal reflection. To overcome these conventional digital clock distribution limitations, optical clock distribution techniques, based on guided-wa...

متن کامل

Multi-objective Measurement Devices Allocation Using State Estimation in Distribution System

Allocation of measurement devices is a necessity of distribution system which is an application of state estimation. In this paper, the problem of active and reactive measurement devices is modeling using a multi-objective method. The objectives of the problem are to minimize the use of measurement devices, increase in state estimation output, improve the state estimation quality and reduce cos...

متن کامل

A New Method to Minimize the Clock Skew to Enhance Performance of Digital System

A Pipe line technology is used in any digital system to perform multiple tasks simultaneously and to reduce the data losses in data transactions. But the conventional pipeline system is facing problems due to improper synchronization of clock pulses. This is a universal problem in all the digital systems mostly called jitter or skew. In most of the digital systems the propagation of informatio...

متن کامل

Salphasic Distribution of Clock Signals

The design of a synchronous system having a global clock must account for the phase shifts experienced by the clock signal (clock skew) in its distribution network. As clock speeds and system diameters increase, this requirement becomes increasingly constraining on system designs. Two currently used approaches to this problem are to minimize skew by equalizing electrical path delays, and to re-...

متن کامل

High-performance and Low-power Clock Branch Sharing Pseudo-NMOS Level Converting Flip-flop

Multi-Supply voltage design using Cluster Voltage Scaling (CVS) is an effective way to reduce power consumption without performance degradation. One of the major issues in this method is performance and power overheads due to insertion of Level Converting Flip-Flops (LCFF) at the interface from low-supply to high-supply clusters to simultaneously perform latching and level conversion. In this p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010