Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study

نویسندگان

  • Tim Bongartz
  • Katrina N Glazebrook
  • Steven J Kavros
  • Naveen S Murthy
  • Stephen P Merry
  • Walter B Franz
  • Clement J Michet
  • Barath M Akkara Veetil
  • John M Davis
  • Thomas G Mason
  • Kenneth J Warrington
  • Steven R Ytterberg
  • Eric L Matteson
  • Cynthia S Crowson
  • Shuai Leng
  • Cynthia H McCollough
چکیده

OBJECTIVES To assess the accuracy of dual-energy CT (DECT) for diagnosing gout, and to explore whether it can have any impact on clinical decision making beyond the established diagnostic approach using polarising microscopy of synovial fluid (diagnostic yield). METHODS Diagnostic single-centre study of 40 patients with active gout, and 41 individuals with other types of joint disease. Sensitivity and specificity of DECT for diagnosing gout was calculated against a combined reference standard (polarising and electron microscopy of synovial fluid). To explore the diagnostic yield of DECT scanning, a third cohort was assembled consisting of patients with inflammatory arthritis and risk factors for gout who had negative synovial fluid polarising microscopy results. Among these patients, the proportion of subjects with DECT findings indicating a diagnosis of gout was assessed. RESULTS The sensitivity and specificity of DECT for diagnosing gout was 0.90 (95% CI 0.76 to 0.97) and 0.83 (95% CI 0.68 to 0.93), respectively. All false negative patients were observed among patients with acute, recent-onset gout. All false positive patients had advanced knee osteoarthritis. DECT in the diagnostic yield cohort revealed evidence of uric acid deposition in 14 out of 30 patients (46.7%). CONCLUSIONS DECT provides good diagnostic accuracy for detection of monosodium urate (MSU) deposits in patients with gout. However, sensitivity is lower in patients with recent-onset disease. DECT has a significant impact on clinical decision making when gout is suspected, but polarising microscopy of synovial fluid fails to demonstrate the presence of MSU crystals.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis of Pneumothorax by Focused Assessment Sonography of Trauma(eFAST) and CT scan in Chest Trauma: Comparison of diagnostic accuracy

Abstract Aims and objectives: Pneumothorax is a common finding after trauma and with a wide range of clinical manifestations, from a concealed pneumothorax detectable only by a CT scan accidentally, to a potentially fatal tension pneumothorax. Pneumothorax can gradually progress to tension pneumothorax and become an emergency, consequently, a timely diagnosis is essential. Most traumatic patie...

متن کامل

Comparing 511 keV Attenuation Maps Obtained from Different Energy Mapping Methods for CT Based Attenuation Correction of PET Data

Introduction:  The  advent  of  dual-modality  PET/CT  scanners  has  revolutionized  clinical  oncology  by  improving lesion localization and facilitating treatment planning for radiotherapy. In addition, the use of  CT images for CT-based attenuation correction (CTAC) decreases the overall scanning time and creates  a noise-free  attenuation  map  (6map).  CTAC  methods  include  scaling,  s...

متن کامل

Effect of the Picture Archiving and Communication System Implementation on the Diagnosis Accuracy of Emergency Physicians in CT Scan Examinations

Introduction: Picture Archiving and Communication System (PACS) allows the processing, archiving, and sharing medical images electronically with different parts of the hospital, especially the emergency department. The aim of this study was to evaluate the effect of PACS on the diagnosis accuracy of emergency department physicians before and after its implementation.  Method: In this analytical...

متن کامل

Effect of the Picture Archiving and Communication System Implementation on the Diagnosis Accuracy of Emergency Physicians in CT Scan Examinations

Introduction: Picture Archiving and Communication System (PACS) allows the processing, archiving, and sharing medical images electronically with different parts of the hospital, especially the emergency department. The aim of this study was to evaluate the effect of PACS on the diagnosis accuracy of emergency department physicians before and after its implementation.  Method: In this analytical...

متن کامل

Comparison of the Diagnostic Values of Four-Point and Two-point Ultrasound Versus CT Scan in Determining Pneumothorax

Background and Objectives: Pneumothorax is a life-threatening complication and the most common cause of which is trauma. Early diagnosis and treatment of Pneumothorax are very important. The aim of this study was to compare the diagnostic values of four-point and double-point ultrasound versus CT scan in determining pneumothorax in Rasul-Akram and Hafte-Tir Hospitals during the years 2015 - 201...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 74  شماره 

صفحات  -

تاریخ انتشار 2015