Temporal analysis of Z-Gradient coil eddy currents in tungsten collimator with different resistivities for SPECT/MRI

نویسندگان

  • Amine Samoudi
  • Karen Van Audenhaege
  • Günter Vermeeren
  • Micahel Poole
  • Luc Martens
  • Roel Van Holen
  • Wout Joseph
چکیده

INTEC, Ghent University/iMinds, Ghent, Belgium Combining Single Photon Emission Computed Tomography (SPECT) with Magnetic Resonance Imaging (MRI) results in an interaction of the time-varying magnetic field gradients with the highly conducting tungsten collimator, which generates a secondary magnetic field causing spatial distortions in reconstructed MR images. Accurate simulations are important for the characterization of these eddy currents and to further optimize the gradient coils and the collimator design. This study investigated the temporal variations of eddy currents in a tungsten collimator for pre-clinical SPECT/MRI due to only the z-gradient coil for different resistivities of tungsten, which can be obtained through additive manufacturing. We modeled a z-gradient coil and a collimator using FEKO, a 3D electromagnetic simulation tool. A time analysis approach was used to generate the pulsed magnetic field gradient. The approach was validated with measurements using a 7T MRI scanner. Simulations show that when tungsten with high resistivity (r=370 nΩ.m) is used, eddy currents generate an added magnetic field representing 1.72 % of the nominal gradient field in a Field Of View (FOV) of 3 cm. This percentage increases rapidly for tungsten with lower resistivities, which was expected since a higher resistivity implies lower current densities. A higher density of tungsten is preferred leading to low resistivity but results in stronger induced eddy currents. A compromise needs to be made between the eddy currents strength and the design of the collimator. Using the insights gained from these simulations, the next step is to optimize the design of the gradient coils and the collimator to further reduce the eddy current effects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of eddy currents induced by transverse and longitudinal gradient coils in different tungsten collimators geometries for SPECT/MRI integration.

PURPOSE We investigated the temporal variation of the induced magnetic field due to the transverse and the longitudinal gradient coils in tungsten collimators arranged in hexagonal and pentagonal geometries with and without gaps between the collimators. METHODS We modeled x-, y-, and z-gradient coils and different arrangements of single-photon emission computed tomography (SPECT) collimators ...

متن کامل

Analysis and reduction of eddy current effects induced by tesseral end zonal gradient coils in different collimator geometries for SPECT/MRI integration

INTEC, Ghent University/iMinds, Ghent, Belgium SPECT and MRI each have their respective advantages and limitations. Combining these two technologies in a synergistic manner allows researchers to exploit the strengths of both techniques but also result in disturbing eddy currents. In this paper, we studied the temporal variation of the induced magnetic field due to the transverse and longitudina...

متن کامل

Coupled circuit numerical analysis of eddy currents in an open MRI system.

We performed a new coupled circuit numerical simulation of eddy currents in an open compact magnetic resonance imaging (MRI) system. Following the coupled circuit approach, the conducting structures were divided into subdomains along the length (or width) and the thickness, and by implementing coupled circuit concepts we have simulated transient responses of eddy currents for subdomains in diff...

متن کامل

FDTD Analysis of transient eddy currents induced by gradient coil switching in MRI

A. Trakic, H. Wang, F. Liu, H. S. Lopez, S. Crozier School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, QLD, Australia Synopsis: Most Magnetic Resonance Imaging (MRI) spatial encoding techniques employ low-frequency pulsed magnetic field gradients that undesirably induce multi-exponentially decaying eddy currents in nearby conducting structures o...

متن کامل

Erratum to: Analysis and reduction of eddy current effects induced by tesseral end zonal gradient coils in different collimator geometries for SPECT/MRI integration

et al. Analysis and reduction of eddy current effects induced by tesseral end zonal gradient coils in different collimator geometries for SPECT/MRI integration. permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014