Use of multifrequency bioelectrical impedance analysis for estimation of total body water and extracellular and intracellular fluid volumes in horses.
نویسندگان
چکیده
OBJECTIVE To evaluate the use of multifrequency bioelectrical impedance analysis (MF-BIA) for estimating total body water (TBW), extracellular fluid volume (ECFV), and intracellular fluid volume (ICFV) in horses. ANIMALS 9 healthy mares. PROCEDURE TBW and ECFV were measured by use of deuterium oxide and sodium bromide dilution techniques, respectively. Intracellular fluid volume was calculated as the difference between TBW and ECFV. Concurrently, MF-BIA recordings were obtained by use of 4 anatomic electrode positions and 3 measurements of length. Models for MF-BIA data were created for all combinations of length and anatomic electrode position. Models were evaluated to determine the position-length configuration that provided the most consistent estimates of TBW, ECFV, and ICFV, compared with values determined by use of the dilution techniques. RESULTS Positioning electrodes over the ipsilateral carpus and tarsus and use of height at the tuber sacrale for length provided the closest estimate between values for TBW, ECFV, and ICFV predicted by use of MF-BIA and measured values obtained by dilutional techniques. This model had the narrowest 95% limits of agreement. CONCLUSIONS AND CLINICAL RELEVANCE MF-BIA techniques have been used to predict changes in TBW, ECFV, and ICFV in healthy and diseased humans. Results reported in this study provide an equine-specific model to serve as the basis for further evaluation of MF-BIA in horses with altered fluid states. The MF-BIA techniques have a number of potential applications for use in horses, including evaluation of exercise physiology, pharmacologic studies, and critical-care management.
منابع مشابه
Multifrequency bioelectrical impedance analysis in women with a normal and hypertensive pregnancy.
BACKGROUND An increase in total body water is common in normal pregnancy. It is thought to be an important mechanism of maternal adaptation to pregnancy. OBJECTIVE The aim of the present study was to assess longitudinal changes in body water compartments in pregnant women and to correlate these measurements with the course of pregnancy. DESIGN One hundred seventy-three pregnant women with a...
متن کاملTotal body water and ECFV measured using bioelectrical impedance analysis and indicator dilution in horses.
The purposes of this study were 1) to determine the compartmentation of body water in horses by using indicator dilution techniques and 2) to simultaneously measure bioelectrical impedance to current flow at impulse current frequencies of 5 and 200 kHz to formulate predictive equations that could be used to estimate total body water (TBW), extracellular fluid volume (ECFV), and intracellular fl...
متن کاملHuman hydrometry: comparison of multifrequency bioelectrical impedance with H2O and bromine dilution
Ellis, Kenneth J., and William W. Wong. Human hydrometry: comparison of multifrequency bioelectrical impedance with H2O and bromine dilution. J. Appl. Physiol. 85(3): 1056–1062, 1998.—The traditional method of assessing total body water (TBW), extracellular water (ECW), and intracellular water (ICW) has been the use of isotopes, on the basis of the dilution principle. Although the development o...
متن کاملSingle- and multifrequency models for bioelectrical impedance analysis of body water compartments.
The 1994 National Institutes of Health Technology Conference on bioelectrical impedance analysis (BIA) did not support the use of BIA under conditions that alter the normal relationship between the extracellular (ECW) and intracellular water (ICW) compartments. To extend applications of BIA to these populations, we investigated the accuracy and precision of seven previously published BIA models...
متن کاملBioelectrical impedance spectroscopy for the assessment of body fluid volumes of term neonates.
The assessment of fluid volume in neonates by a noninvasive, inexpensive, and fast method can contribute significantly to increase the quality of neonatal care. The objective of the present study was to calibrate an acquisition system and software to estimate the bioelectrical impedance parameters obtained by a method of bioelectrical impedance spectroscopy based on step response and to develop...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of veterinary research
دوره 65 3 شماره
صفحات -
تاریخ انتشار 2004