Generation of an X-ray microbeam for spectromicroscopy at SPring-8 BL39XU.
نویسندگان
چکیده
A pair of elliptical mirrors (KB mirror) was designed and fabricated to realize an energy tunable x-ray microbeam for spectromicroscopy at SPring-8 BL39XU. As is commonly recognized, the obtainable beam size with the aspherical total reflection mirrors is strongly affected with the slope error of the mirror. Considering that the extremely high brilliance of the undulator radiation from the SPring-8, the small mirror size and the small mirror-to-focus distance were employed to minimize effects of the slope error. Preliminary evaluation of the KB mirror was carried out using 10 keV monochromatized undulator radiation. Alignment of the mirror was assisted by the beam monitor system composed of a scintillator and a CCD, and the beam size less than 5 microm can be easily achieved even when the source was fully used. The beam size obtained with this experiment was 2 x 4 microm2 with the photon flux of 1 x 10(10) photons/s. Smaller beam size may be expected with the use of intermediate slits. Characterization of trace elements with the spatial resolution will be carried out by using x-ray fluorescence (XRF) analysis and x-ray absorption fine structure (XAFS) measurements with XRF yield method.
منابع مشابه
A hard X-ray nanospectroscopy station at SPring-8 BL39XU
We upgraded the hard X-ray spectroscopy beamline BL39XU at SPring-8 by installing Kirkpatrick-Baez mirrors to equip it with submicron-focusing capability. At the new experimental end-station located 74 m from the undulator source, an X-ray nanoprobe with a size of 120 × 100 nm has become available at 5–16 keV. This upgrade is fully compatible with the X-ray polarization tunability and helicity-...
متن کاملImaging of vascular smooth muscle cells with soft X-ray spectromicroscopy.
Using X-ray microscopy and spectromicroscopy, vascular smooth muscle cells (VSMCs) were imaged, prepared without using additional embedding material or staining, but by applying simple, noncryo fixation techniques. The cells were imaged with a compact source transmission X-ray microscope and a scanning transmission X-ray microscope (STXM). With the STXM, spectromicroscopy was performed at the C...
متن کاملA Microbeam Small-Angle X-ray Scattering Study on Enamel Crystallites in Subsurface Lesion
The early caries lesion in bovine tooth enamel was studied by two different X-ray diffraction systems at the SPring-8 third generation synchrotron radiation facility. Both allowed us simultaneous measurement of the small and large angle regions. The beam size was 6μm at BL40XU and 50μm at BL45XU. The small-angle scattering from voids in the hydroxyapatite crystallites and the wide-angle diffrac...
متن کامل50-nm-resolution full-field X-ray microscope without chromatic aberration using total-reflection imaging mirrors
X-ray spectromicroscopy with a full-field imaging technique is a powerful method for chemical analysis of heterogeneous complex materials with a nano-scale spatial resolution. For imaging optics, an X-ray reflective optical system has excellent capabilities with highly efficient, achromatic, and long-working-distance properties. An advanced Kirkpatrick-Baez geometry that combines four independe...
متن کاملOptical klystron FEL scheme for x-ray coherent harmonic generation at ISLF storage ring
The possibility of inserting an optical klystron on the storage ring of an Iranian Light Source Facility as a Synchrotron Radiation Free electron Laser for coherence harmonic generation in the soft x-ray spectrum has been studied. The study has been performed using the 3D FEL simulation code GENESIS 1.3 and in accordance with the available characteristic parameters of ISLF. Different potential ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of synchrotron radiation
دوره 8 Pt 2 شماره
صفحات -
تاریخ انتشار 2001