Effect of Inlet and Outlet Flow Conditions on Natural Gas Parameters in Supersonic Separation Process

نویسندگان

  • Yan Yang
  • Chuang Wen
  • Shuli Wang
  • Yuqing Feng
  • Gongnan Xie
چکیده

A supersonic separator has been introduced to remove water vapour from natural gas. The mechanisms of the upstream and downstream influences are not well understood for various flow conditions from the wellhead and the back pipelines. We used a computational model to investigate the effect of the inlet and outlet flow conditions on the supersonic separation process. We found that the shock wave was sensitive to the inlet or back pressure compared to the inlet temperature. The shock position shifted forward with a higher inlet or back pressure. It indicated that an increasing inlet pressure declined the pressure recovery capacity. Furthermore, the shock wave moved out of the diffuser when the ratio of the back pressure to the inlet one was greater than 0.75, in which the state of the low pressure and temperature was destroyed, resulting in the re-evaporation of the condensed liquids. Natural gas would be the subsonic flows in the whole supersonic separator, if the mass flow rate was less than the design value, and it could not reach the low pressure and temperature for the condensation and separation of the water vapor. These results suggested a guidance mechanism for natural gas supersonic separation in various flow conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Effects of Inlet Conditions and Nozzle Geometry on the Performance of Supersonic Separator Used for Natural Gas Dehumidification

Supersonic separators have found extensive applications in dehumidification of natural gases since 2003. Unlike previous studies, which have investigated the inlet conditions and nozzle geometry of supersonic separators for pure fluids, the present study employed a combination of momentum, heat, and mass transfer equations along with Virial equation of state (EOS) to inspect the effect of inlet...

متن کامل

A CFD Simulation of the Parameters Affecting the Performance of Downhole De-oiling Hydrocyclone

Among the all parameters affecting the performance of a downhole de-oiling hydrocyclone, the investigation of internal flow field deserves more attempts especially in the petroleum industry. In this study, the effects of inlet flow rate, inlet oil volume fraction, and oil droplet diameter on the separation efficiency and pressure drop ratio have been investigated along the hydrocyclone body. Al...

متن کامل

Investigating the effect of Inlet and Outlet location on Flow field and Sedimentation pattern of a rectangular settling basin using CCHE2D

Water obtained from any source may contain impurities induced by erosion, dissolved minerals, dissolved gases and material produced from organic matter decomposing. If the amount of these substances exceed a certain limit, not only the water would not be potable, but the water containing the material will not be suitable to be used in most applications, or at least before treatment cannot be ap...

متن کامل

Thermal performance analysis of intermediate fluid vaporizer for liquefied natural gas

The intermediate fluid vaporizer (IFV) is a new kind of vaporizer for liquefied natural gas (LNG). A thermal model was established based on the energy balance among the three typical parts of IFV, namely, evaporator, condenser and thermolator, whose mutual coupling and constraints were fully considered. Calculation codes were developed to solve the energy balance equations, in which the formula...

متن کامل

Influence of unsuitable operational conditions on the transient performance of a small hydrogen liquefier

Joule-Thomson cooling systems are used in refrigeration processes such as cryogenic gas liquefaction. Although extensive studies have been carried out by researchers, most of them include cryogenic heat exchangers and their associated fields. In the current study, an attempt was made to indicate the effect of using inappropriate operational conditions in a cryogenic Joule-Thomson cooling system...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014