Investigations on permeation of mitomycin C through double layers of natural rubber gloves.

نویسندگان

  • Gintautas Korinth
  • Klaus Schmid
  • Oliver Midasch
  • Melanie I Boettcher
  • Jürgen Angerer
  • Hans Drexler
چکیده

Treating peritoneal carcinomatosis by the aggressive cytoreductive surgery with the hyperthermic intraoperative intraperitoneal chemotherapy (HIPEC) surgeons expose their gloved hands for up to 90 min to a peritoneal dialysis solution (PDS) containing mitomycin C (MMC). We investigated the permeation of MMC through the material of three different natural rubber gloves under conditions similar to the in-use during HIPEC as well as under worst-case exposure scenario. Two different methods, a two-chamber diffusion cell and a single-chamber glass chamber method, were used to demonstrate the permeation capability. The permeation of MMC dissolved in 0.9% NaCl solution and PDS through double natural rubber glove material was tested over 2 h using four concentrations (c = 0.004, 0.008, 0.016 and 0.4 mg ml(-1)) and three receptor fluids (0.9% NaCl solution, PDS and a novel artificial sweat). In none of four glass chamber experiments and in only one of 40 diffusion cell experiments was permeation through glove material detected. The permeation occurred between 15 and 30 min under worst-case exposure scenario at a approximately 100-fold higher MMC concentration than under in-use conditions during HIPEC. The double-layer natural rubber gloves tested were effective to prevent a permeation of MMC in vitro under HIPEC-similar exposure. Our results support the glove wearing procedure in our university hospital. However, occupational exposure to antineoplastic drugs should be minimized, since there is insufficient knowledge regarding harmful effects from a long-term exposure to low doses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The permeability of surgical gloves to seven chemicals commonly used in hospitals.

Disinfectants may cause adverse effects directly on the skin or systemically by permeating through the skin. In this study breakthrough times were measured for surgical gloves with chemicals which are commonly used in healthcare. Classical methods of analytical chemistry were tailored for the permeation tests, which were carried out according to the European standard EN 374 and the American sta...

متن کامل

Resistance of gloves and protective clothing materials to permeation of cytostatic solutions.

OBJECTIVES The objective of the work was to determine the resistance of selected protective clothing and glove materials to permeation of cytostatics such as docetaxel, fluorouracil, and doxorubicin. MATERIAL AND METHODS The following glove materials were used: natural rubber latex (code A), acrylonitrile-butadiene rubber (code B) and chloroprene rubber (code C). In addition, we tested a laye...

متن کامل

Permeability of hair dye compounds p-phenylenediamine, toluene-2,5-diaminesulfate and resorcinol through protective gloves in hairdressing.

Dermal exposure to skin irritants and contact allergens is frequent in hairdressing. Hair dyeing is popular today and involves exposure to highly potent contact allergens, such as p-phenylenediamine (PPD). Use of protective gloves to prevent contact with skin-damaging substances is essential. The aim of the present study was to determine the resistance to permeation by PPD, toluene-2,5-diamines...

متن کامل

Permeation of hair dye ingredients, p-phenylenediamine and aminophenol isomers, through protective gloves.

Skin irritation and contact allergies are skin disorders common to hairdressers. The predominant oxidative hair dye components, such as p-phenylenediamine (PPD) and aminophenol isomers, can cause contact dermatitis. Use of protective gloves can prevent dermal contact with skin irritants. This study investigates the permeation behaviors of p-aminophenol (PAP), m-aminophenol (MAP), o-aminophenol ...

متن کامل

Permeation of multifunctional acrylates through selected protective glove materials.

In support of the Premanufacture Notification (PMN) program of the Environmental Protection Agency's Office of Toxic Substances, the resistance of three glove materials to permeation by multifunctional acrylate compounds was evaluated through a program for the Office of Research and Development. Several recent PMN submissions relate to multifunctional acrylates and essentially no permeation dat...